Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

RELAP5 Assessment Against PACTEL Experimental Data (NUREG/IA-0145, Revision 1)

On this page:

Download complete document

Publication Information

Date Published: November 1998

Prepared by:
I. Parzer, B. Mavko, S. Petelin

University of Ljubljana
"Jozef Stefan" Institute
P.O. Box 100
61111 Ljubljana
Slovenia

Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Code Application and Maintenance Program (CAMP)

Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

The results of the pre-test and post-test calculations of OECD International Standard Problem no.33 (ISP-33) are presented. The frozen version of RELAP5 code version MOD2 and the latest released version MOD3.2 have been assessed against experimental data from PACTEL facility. Generally, predictions were in good agreement with experimental data, except in the most interesting part of the transient only MOD3.2 was able to follow periodic hot leg loop seal clearance phenomena and primary pressure oscillations closely.

Page Last Reviewed/Updated Tuesday, March 09, 2021