Power Reactor Status Report for August 27, 2011

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100   HURRICANE WARNING ONSITE *  
Indian Point 2 100   SEVERE WEATHER PREPS    
Indian Point 3 100   SEVERE WEATHER PREPS    
Limerick 1 100   CONSERVATIVE OPERATIONS *  
Limerick 2 100   CONSERVATIVE OPERATIONS *  
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100   HURRICANE WARNING ONSITE *  
Peach Bottom 2 100   CONSERVATIVE ACTIONS *  
Peach Bottom 3 92   COASTDOWN TO REFUELING OUTAGE; CONSERVATIVE ACTIONS *  
Pilgrim 1 100        
Salem 1 100        
Salem 2 100        
Seabrook 1 100   ISO NO GENERATION RISK *  
Susquehanna 1 100        
Susquehanna 2 100     *  
Three Mile Island 1 100        
Vermont Yankee 100   ISO NO GENERATION RISK *  

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 70   DOWNPOWER FOR HURRICANE RESPONSE *  
Brunswick 2 70   DOWNPOWER FOR HURRICANE RESPONSE *  
Catawba 1 100        
Catawba 2 100        
Crystal River 3 0 09/25/2009 DEFUELED; CONTAINMENT TENSIONING ON HOLD    
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 72   PLANT TESTING *  
McGuire 1 100        
McGuire 2 100        
North Anna 1 0 08/23/2011 NOUE DUE TO AFTERSHOCK EARTHQUAKE (EN #47196)    
North Anna 2 0 08/23/2011 NOUE DUE TO AFTERSHOCK EARTHQUAKE (EN #47196) *  
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 70   INCREASING POWER *  
Saint Lucie 2 100     *  
Sequoyah 1 100        
Sequoyah 2 100        
Summer 99     *  
Surry 1 100   TROPICAL STORM WARNING ONSITE *  
Surry 2 100   TROPICAL STORM WARNING ONSITE *  
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 100        
Dresden 3 100        
Duane Arnold 100        
Fermi 2 100        
Kewaunee 100        
La Salle 1 100        
La Salle 2 69   PLANT TESTING *  
Monticello 56   CONDENSATE PUMP MAINTENANCE *  
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 0 04/02/2011 REFUELING OUTAGE    
Comanche Peak 1 61   MAIN FEEDPUMP MAINTENANCE *  
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 0 04/09/2011 REFUELING OUTAGE - NOUE FOR MISSOURI RIVER WATER LEVEL - EN #46929    
Grand Gulf 1 96   2ND STAGE MSR LIMITED TO 96% POWER    
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 100        
San Onofre 3 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.

Page Last Reviewed/Updated Friday, March 30, 2012