The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Part 21 Report - 2000-270

GIRARD DEVELOPMENT INC.

P.O. BOX 338� RANCHO CORDOVA, CA 95741�916/635-8159

10/24/00

U.S. Nuclear Regulatory Commission

Washington, DC 20555

Attn: Office of Nuclear Material Safety and Safeguards

Dear Sirs;

In accordance with 10CFR Part 21 I wish to report a non conformance of Tube Clamps shipped to various Nuclear Power Plants. The clamps were marked with our part number 3/4-1 T-55 l SS-2D but were actually clamps, part number 3/4-1T-551SS-3D.

Following are the plants the clamps were shipped to with their purchase order numbers and date.

PLANT DATE P.O. OUR DEL. HEAT QUANTITY

NUMBER NUMBER CODE

Calvert Cliffs 12/4/98 32770 5363N 81198 30

Indian Point 4/15/99 9509175 5438N 81199 5

Point Beach 10/14/99 4500276623 5548N 81199 20

Clamps from heat codes 81198 and 81199 were the only ones affected.

The person responsible is Don Girard (916/635-8159).

All plants have been notified and they have been requested to return the clamps so the correct ones can be supplied.

Very Truly Yours,

Don Girard