The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Part 21 Report - 2000-200

SCIENTECH

910 Clopper Road Gaithersburg MD 20878-1399 Phone 301-258-2410 Fax 301-258-2463

September 19, 2000

NRC Operations Center
Document Control Desk
1 White Flint North
11555 Rockville Pike
Bethesda, MD 20852

POTENTIAL DEFECT UNDER 10CFR21

Dear Sir or Madam:

SCIENTECH, Inc.'s subsidiary NUS Instruments, Inc. (NUSI) has determined that a Basic Component, supplied to Rochester Gas & Electric Ginna Station Nuclear Plant under RG&E purchase order NQ-15877-A-JW, may contain a defect that is reportable under 10CFR21. NUSI became aware of this potential defect September 14, 2000. SCIENTECH, Inc. President was informed September 19, 2000. RG&E is aware of this problem and the affected components have been modified to remove any undesirable effects on their systems. A formal written report will be provided within 30 days of this notification. The components, Delta T Time Domain Modules, M/N: TMD500-08/08/08/08-15-08-01/2, P/N: MBA-E062PA-1, Rev. 0 (4 ea.), were manufactured by NUSI. These components have been supplied to no other utility for use in Safety Related Systems. NUSI has opened a 10CFR21 file concerning this component and has numbered it as 21-00-01.

SCIENTECH/NUSI Contacts

Martin Booska
Scientech QA Representative
(301) 387-7012

Paul Loch
President
(407) 333-8895

If you have any questions or comments, please feel free to call.

Sincerely,

Paul Loch
President, SCIENTECH, Inc.

09/20/2000 U.S. Nuclear Regulatory Commission Operations Center Event Report

General Information or Other (PAR) Event# 37354

Rep Org: SCIENTECH/NUSI Notification Date / Time: 09/20/2000 07:42 (EDT)
Supplier: SCIENTECH/NUSI Event Date / Time: 09/14/2000 (EDT)
Last Modification: 09/20/2000
Region: 1 Docket #:
City: GAITHERSBURG Agreement State: Yes
County: License #:
State: MD
NRC Notified by: BOOSKA Notifications: WILLIAM RULAND RI
HQ Ops Officer: CHAUNCEY GOULD VERN HODGE NRR
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 UNSPECIFIED PARAGRAPH

PART 21 RELATED TO DEFECTS IN DELTA T TIME DOMAIN MODULES SUPPLIED TO GINNA STATION

SCIENTECH, Inc.'s subsidiary NUS Instruments, Inc. (NUSI) has determined that a Basic

Component, supplied to Rochester Gas & Electric Ginna Station Nuclear Plant under RG&E purchase order NQ-15877-A-JW, may contain a defect that is reportable under 10CFR21. NUSI became aware of this potential defect September 14, 2000. SCIENTECH, Inc. President was informed September 19, 2000. RG&E is aware of this problem and the affected components have been modified to remove any undesirable effects on their systems. A formal written report will be provided within 30 days of this notification. The components, T Time Domain Modules, M/N: TMD500-08/08/08/08-15-08-01/2, P/N: MBA-E062PA-1, Rev. 0 (4 ea.), were manufactured by NUSI. These components have been supplied to no other utility for use in Safety Related Systems. NUSI has opened a 10CFR21 file concerning this component and has numbered it as 21-00-01.

Page Last Reviewed/Updated Thursday, March 25, 2021