Girard development inc.

P.O.  BOX 338 o RANCHO CORDOVA, CA 95741 o 916/635-8159



Document Control Desk

Nuclear Regulatory Commission

Washington D.C.  20555



Indian Point Station                                   8/3/98

Broadway & Bleakley Ave.

Buchanan, NY 10511



Attn: Vice President of Nuclear Power



                          10CFR21 NOTIFICATION



Your Purchase Order #8508061, release 0

Our Delivery # 5231N shipped on 2/15/98

Our Heat Code #73520

Part #3/8-1/2T-500SS-2D



Material was ASTM A351, GR. CF8



Subsequent tests showed the material was out of specifications in

molybdenum & chromium,



               Spec.               Heat Code 73520

molybdenum     .50 max             .93

chromium       18.0-21.0           17.76





                                        Don Girard