The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Part 21 Report - 1998-136

ACCESSION #: 9806160464 The Boeing Company P.O. Box 3707 Seattle, WA 98124-2207 June 10, 1998 G-1151-SJA-98-288 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 BOEING Reference: a) Boeing Letter G-1 151 -RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator Phone: (425) 865-6248 FAX: (425) 865-4851 Mail Stop: 7A-33, or e-mail: Sandra.J.Andrews@Boeing.com Enclosure(s): GTSTRUDL Program report form 98.08 Georgia Institute JUN 08 1998 of Technology GTSTRUDL[Registered Trademark] May 29, 1998 Attention: Nuclear Administrator Boeing Information & Support Services P.O.Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 98.08, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center David C. Key Configuration Control Manager Enclosures Computer Aided Structural Engineering Center Phone: (404) 894-2260 School of Civil & Environmental Engineering Fax: (404) 894-8014 Atlanta, Georgia 30332-0355 USA casec@ce.gatech.edu A Unit of the University System of Georgia GTSTRUDL Program Report Form GPRF No.: 98.08 DATE: 5/26/98 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: _ URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _MINOR Problem can be worked around or problem poses high frustration factor. xINFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed May 26, 1998 Date Notification Sent Computers All Operating System All Versions: All Target Release for Correction: 9801 NT Verification Manual Signature Title R & D Division Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 98.08 DATE: 5/26/98 DESCRIPTION: There were several errors discovered in the GTSTRUDL Verification Manual in the course of a recent review. These issues are as follows: 1. In VDY11, the second equation on page 3.11-1 is missing the minus sign in front of the 'e'. 2. In the problem description for VRC05, the GTSTRUDL design matched the Reference design, except that the problem description should have stated 100 k-ft and 80 k-in instead of 100 k-in and 80 k-in. The actual run used the proper units, only the manual is incorrect. 3. For VTA15, some of the values listed in the tables have their values switched. The formulas specified on page 8.15-3 and 8.15-4 are incorrect for iy iz sy sz ry rz, causing the values for y and z to be reversed in the table on pages 8.15-5 and 8.15-6. The correct formulas were used to create the properties in the GTSTRUDL tables, only the manual is incorrect. Rev. 2.2 *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021