Event Notification Report for July 30, 2012
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 07/27/2012 - 07/30/2012 ** EVENT NUMBERS ** | | Agreement State | Event Number: 48118 | Rep Org: WISCONSIN RADIATION PROTECTION Licensee: WHEATON FRANCISCAN HEALTHCARE - ALL SAINTS Region: 3 City: RACINE State: WI County: License #: 101-1299-01 Agreement: Y Docket: NRC Notified By: EMILY EGGERS HQ OPS Officer: DONALD NORWOOD | Notification Date: 07/19/2012 Notification Time: 17:06 [ET] Event Date: 07/19/2012 Event Time: [CDT] Last Update Date: 07/19/2012 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): LAURA KOZAK (R3DO) FSME via E-mail () | Event Text AGREEMENT STATE REPORT - 15 PROSTATE BRACHYTHERAPY MEDICAL EVENTS The following information was received via facsimile: "On July 19, 2012, the licensee reported the identification of 15 medical events that were discovered on July 18, 2012, involving permanent implants of iodine-125 for prostate brachytherapy where the total dose delivered differs from the prescribed dose by 20% or more. During a recent inspection, DHS [Department of Health Services] inspectors determined that the licensee was not reviewing prostate brachytherapy cases against the medical event criteria. The licensee established dose based criteria used by post-operation CT, prostate D90 values <80% or >130% for classifying medical events. The licensee has evaluated all prostate implants performed since 2001. "--Overdose to the prostate (medical event criteria used -D90>130%): 08/20/2009: 137.3% "--Underdose to the prostate (medical event criteria used -D90<80%): 07/15/2005: 79.27% 03/13/2006: 79.17% 03/15/2006: 67.10% 07/26/2006: 72.35% 07/26/2006: 57.06% 02/13/2006: 78.37% 05/14/2009: 78.67% "--Overdose to the rectum (medical event criteria used -V100>2cc): 12/13/2006: 2.42cc 12/19/2007: 2.23cc 03/03/2009: 2.54cc 07/08/2009: 3.32cc 11/19/2009: 2.89cc 05/05/2010: 2.41cc 05/20/2010: 3.92cc "DHS inspectors conducted an investigation of these medical events and are awaiting completion of the licensee's review." Wisconsin Event Report ID No.: WI120008 A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | | Power Reactor | Event Number: 48141 | Facility: ARKANSAS NUCLEAR Region: 4 State: AR Unit: [1] [2] [ ] RX Type: [1] B&W-L-LP,[2] CE NRC Notified By: JAMES CRABILL HQ OPS Officer: JOHN SHOEMAKER | Notification Date: 07/27/2012 Notification Time: 00:29 [ET] Event Date: 07/26/2012 Event Time: 21:20 [CDT] Last Update Date: 07/27/2012 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): JAMES DRAKE (R4DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text LOSS OF AC POWER TO THE EMERGENCY OPERATIONS FACILITY "At 2120 [CDT] [on 07/26/12], a loss of AC power to the Emergency Operations Facility (EOF) occurred effecting emergency response capability. The Technical Support Center (TSC) remained available. In the event of on emergency declaration requiring an EOF, the emergency Response Organization (ERO) would have been directed to report to the Backup EOF. "Assessment capability via SPDS was not lost during this time period and communications equipment also remained available. "Coincident with no local offsite power being available, the backup diesel generator was unable to supply AC power to the facility due to an overvoltage condition present on the transfer switch. No power was available from the time period of 2120 [CDT] to 2133 [CDT] when local offsite power was restored to the building. "This notification is being made in accordance with 10 CFR 50.12(b)(3)(xiii) due to the unavailability of an emergency response facility." The licensee has notified the NRC Resident Inspector. | |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021