Technical Report on Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping (NUREG-0313, Revision 2)
On this page:
Download complete document
Publication Information
Manuscript Completed: July 1987
Date Published: January 1988
Prepared by:
W. S. Hazelton, W. H. Koo
Division of Engineering and Systems Technology
Office of Nuclear Reactor Regulation
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
This report updates and supersedes the technical recommendations of NUREG-0313, "Technical Report on Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping," published in July 1977, and its subsequent revision published in July 1980.
This report provides the technical bases for the NRC staff's revised recommended methods to control the intergranular stress corrosion cracking susceptibility of BWR piping. For piping that does not fully comply with the material selection, testing, and processing guideline combinations of this document, varying degrees of augmented inservice inspection are recommended. This revision also includes guidance and NRC staff recommendations (not requirements) regarding crack evaluation and weld overlay repair methods for long-term operation or for continuing interim operation of plants until a more permanent solution is implemented.
Page Last Reviewed/Updated Wednesday, April 27, 2022
Page Last Reviewed/Updated Wednesday, April 27, 2022