Fort Saint Vrain Gas Cooled Reactor Operational Experience (NUREG/CR-6839, ORNL/TM-2003/223)
On this page:
Download complete document
Publication Information
Manuscript Completed: September 2003
Date Published: January 2004
Prepared by:
D.A. Copinger, D.L. Moses
Oak Ridge National Laboratory
Oak Ridge, Tennessee 37831-6487
Managed by UT-Battelle, LLC
L.R. Cupidon, NRC Program Manager
Prepared for:
Division of Systems Analysis and Regulatory Effectiveness
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
NRC Job Code Y6695
Abstract
Oak Ridge National Laboratory (ORNL) performed an operational events assessment of Fort St. Vrain (FSV) nuclear power plant during 1981–1989. As part of that assessment, the ORNL principal investigator filed 96 monthly reports detailing the results of each month's analysis. This project reviewed those 96 monthly reports and identified pertinent operating experiences that occurred at FSV which may be applicable to current or future gas cooled reactor (GCR) designs.
Two hundred seventy-nine events were catalogued into seven general categories: (1) water incursion events or failures of moisture detection systems; (2) air or other unwanted gas incursion events and failures of gas detection systems; (3) fuel failures or anomalies; (4) failures or cracks in graphite, pipes, and other reactor structural components; (5) failures of nuclear instrumentation systems; (6) human factors and operator performance issues; and (7) other events or conditions that may be relevant to current GCR designs. Several events were reviewed over a period of years and appeared in more than one monthly report.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021