The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Simulation with RELAP5/MOD3.3 of an Integral-Effect Test on Loop-Seal Clearing in the Upper Plenum Test Facility During Test A5 (NUREG/IA-0520)
On this page:
Download complete document
Publication Information
Manuscript Completed: July 2019
Date Published: June 2020
Prepared by:
Richard Trewin
Framatome GmbH
Paul-Gossen-Str. 100
91058 Erlangen, Germany
K. Tien, NRC Project Manager
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
Under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)
Published by:
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
The RELAP5/MOD 3.3 computer code has been used to simulate an experiment on loop-seal clearing conducted in the Upper Plenum Test Facility. An assessment of this code version was performed by comparing the calculated results to the measured data from the experimental facility.
Loop-seal clearing in a pressurized-water reactor during an intermediate-break loss-of-coolant accident was investigated in the UPTF-TRAM experimental facility during a series of experiments designated Test A5. The phenomenon of loop-seal clearing was studied at 15 bar(a) during an integral-effects test designated ITRun2a.
This report presents assessments that demonstrate the suitability of the code for analyzing loop-seal clearing transients.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021