The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
RELAP5/MOD2 Post-Test Calculation of the OECD LOFT Experiment LP-SB-1 (NUREG/IA-0074, ICSP–LP–SB–1–R)
On this page:
Download complete document
Publication Information
Date Published: April 1992
Prepared by:
J. Perez, R. Mendizabal
Consejo de Seguaridad Nuclear
Justo Dorado, 44
28040 Madrid, Spain
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
This document presents the analysis of the OECD LOFT LP-SB-1 experiment performed by the Consejo de Seguridad Nuclear of Spain working group making use of RELAP5/MOD2 in the frame of the Spanish LOFT Project.
LP-SB-1 experiment studies the effect of an early pump trip in a small break LOCA scenario with a 3 inches equivalent diameter break in the hot leg of a commercial PWR.
Page Last Reviewed/Updated Tuesday, March 09, 2021