TRAC–PF1 Code Assessment Using OECD LOFT LP–FP–1 Experiment (NUREG/IA–0050, ICSP–LP–FP–1)
On this page:
Download complete document
Publication Information
Date Published: April 1992
Prepared by:
F. J. Barbero
Centro de Investigaciones Energeticas
Medioambientales y Tecnologicas
Consejo de Seguridad Nuclear
Madrid, Spain
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
Document resumes the final calculations of the thermal-hydraulic aspects of the OECD LOFT-LP-FP-1 experiment, with emphasis in those related with the assessment of the TRAC-PF1 code.
LOFT LP-FP-1 experiment was carried out at the LOFT facility in INEL, sponsored by the OECD.
Code used for this simulation was TRAC-PF1/Mod 1 (version 11.0) running on a CDC Cyber 830 (O.S. NOS-BE).
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021