The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Assessment of RELAP5/MOD2, Cycle 36.04 Against LOFT Small Break Experiment L3-6 (NUREG/IA-0033)
On this page:
Download complete document
Publication Information
Date Published: July 1990
Prepared by:
John Eriksson
Swedish Nuclear Power Inspectorate
S-102 52 Stockholm, Sweden
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Published by:
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555
Abstract
The LOFT small break experiment L3-6 has been analyzed as part of Sweden's contribution to the International Thermal-Hydraulic Code Assessment and Applications Program (ICAP).
Three calculations, of which two were sensitivity studies, were carried out. The following quantities were varied:
the content of secondary side fluid and the feed water valve closure
the two-phase characteristics of the main pumps
All three predictions agreed reasonably well with most of the measured data. The sensitivity calculations resulted only in marginal improvements. The predicted and measured data are compared on plots and their differences are quantified over intervals in real time.
Page Last Reviewed/Updated Tuesday, March 09, 2021