Assessment of RELAP5/MOD2, Cycle 36.04 Against FIX-II Split Break Experiment No. 3051 (NUREG/IA-0029)
On this page:
Download complete document
Publication Information
Date Published: October 1989
Prepared by:
J. Eriksson
Swedish Nuclear Power Inspectorate
S-61182 Nykoping, Sweden
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Published by:
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555
Abstract
The FIX-II split break experiment No. 3051 has been analyzed using the RELAP5/MOD2 code. The code version used, Cycle 36.04, is the frozen version of the code.
Three calculations were carried out to study the sensitivity of various parameters to the change of break discharge and passive heat structures. The differences between the calculations and the experiment have been quantified over intervals in real time for a number of variables available from the measurements during the experiment.