Skip to main content

Alert

The NRC is shutdown due to the lapse in appropriations. Exempted activities to maintain critical health and safety activities and progress on critical activities, including activities outlined in Executive Order 14300, as described in the OMB Approved NRC Lapse Plan will continue.

RELAP/MOD2 Calculations of OECD-LOFT Test LP-SB-03 (NUREG/IA-0013)

On this page:

Download complete document

Publication Information

Date Published: January 1990

Prepared by:
C. Harwood, G. Brown

Central Electricity Generating Board
Barnwood, Gloucester
GL4 7RS
United Kingdom

Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)

Published by:
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555

Availability Notice

Abstract

This report compares the results of the RELAP5/MOD2 analysis with experimental measurements.

A simulation of test LP-SB-03 was previously carried out at GDCD using the RELAP5/MOD1 code. RELAP5/MOD2 was developed from RELAP5/MOD1 and contains more sophisticated hydraulic models and constitutive relationships. Comparison of the RELAP5/MOD2 and MODI calculations show that RELAP5/MOD2 performs better than RELAP5/MOD1 in a number of key areas; notably mass errors are much reduced, there is improved numerical stability, and improved separator modelling and modelling of accumulator injection.

Page Last Reviewed/Updated Tuesday, March 09, 2021

Page Last Reviewed/Updated Tuesday, March 09, 2021