Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

RELAP/MOD2 Calculations of OECD-LOFT Test LP-SB-03 (NUREG/IA-0013)

On this page:

Download complete document

Publication Information

Date Published: January 1990

Prepared by:
C. Harwood, G. Brown

Central Electricity Generating Board
Barnwood, Gloucester
GL4 7RS
United Kingdom

Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)

Published by:
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555

Availability Notice

Abstract

This report compares the results of the RELAP5/MOD2 analysis with experimental measurements.

A simulation of test LP-SB-03 was previously carried out at GDCD using the RELAP5/MOD1 code. RELAP5/MOD2 was developed from RELAP5/MOD1 and contains more sophisticated hydraulic models and constitutive relationships. Comparison of the RELAP5/MOD2 and MODI calculations show that RELAP5/MOD2 performs better than RELAP5/MOD1 in a number of key areas; notably mass errors are much reduced, there is improved numerical stability, and improved separator modelling and modelling of accumulator injection.