The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Assessment of RELAP5/MOD 2 Against Marviken Jet Impingement Test 11 Level Swell (NUREG/IA-0006)
On this page:
Download complete document
Publication Information
Date Published: September 1986
Prepared by:
0. Rosdahl, D. Caraher
Swedish Nuclear Power Inspectorate
P.O. Box 27106
S102 #52 Stockholm, Sweden
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Published by:
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555
Abstract
RELAP5/MOD2 simulations of level swell of saturated liquid in a large (5 m diameter, 22 m high) vessel are reported. For certain nodalizations RELAP5 is shown to predict the measured void fraction profile with fair accuracy. RELAP5 results are shown to be dependent upon nodalization with the accuracy of computed results deteriorating significantly when a large number of nodes is employed.
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021