The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Transmittal of NUREG-0909 Relative to the Ginna Tube Rupture (Generic Letter No. 82-07)



                                UNITED STATES
                       NUCLEAR REGULATORY COMMISSION  
                           WASHINGTON, D.C. 20555 

                               April 15, 1982 

TO ALL BOILING WATER REACTOR PLANT LICENSEES AND APPLICANTS 

Gentlemen: 

SUBJECT:  TRANSMITTAL OF NUREG-0909 RELATIVE TO THE GINNA TUBE RUPTURE 
          (Generic Letter No. 82-07) 

On January 25, 1982, the R. E. Ginna Nuclear Power Plant experienced a 
rupture of a steam generator tube. Shortly after the event, Chairman 
Palladino directed that a task force be established to gather and report on 
the factual information surrounding the event. 

The task force has now completed its investigation and has documented the 
factual information and their findings associated with the event (See 
Enclosed NUREG-0909). 

This report is being provided for your information only. 

                                   Sincerely, 


                                   Darrell G. Eisenhut, Director 
                                   Division of Licensing 
                                   Office of Nuclear Reactor Regulation 

Enclosure:
NUREG-0909




8204160152 
 

Page Last Reviewed/Updated Tuesday, March 09, 2021