Discussion Of Lessons Learned Short Term Requirements (Generic Letter 79-61)
GL79061
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D. C. 20555
November 9, 1979
TO ALL PENDING CONSTRUCTION PERMIT APPLICANTS
Gentlemen:
SUBJECT: DISCUSSION OF LESSONS LEARNED SHORT TERM REQUIREMENTS
On October 10, 1979, you received a letter which defined a set of "short
term" requirements resulting from the NRC staff investigations of the TMI
accident. Since the letter was issued, the staff has further defined these
requirements.
Enclosure 1 provides the additional clarifications of the NRC staff
requirements as provided to licensees of operating reactors. Enclosure 2
provides a list of modifications to these clarifications to make them
applicable to duplicants for operating licenses, applicants for construction
permits and licensees of plants under construction. It should be noted that
the intent of these requirements and the purpose of our letter of October
10, 1979 have not changed.
If you have any questions regarding these actions, please contact the NRC
Project Manager for your facility.
Sincerely,
D. B. Vassallo, Acting Director
Division of Project Management
Office of Nuclear Reactor Regulation
Enclosure:
Discussion of TMI Lessons Learned
Short Term Requirements
ccs:
Service List
UNDER CP REVIEW
1. Pilgrim Boston Edison
2. Greenwood Detroit Edison
3. Perkins Duke Power
4. Allens Creek Houston Lighting & Power
5. New England New England Power & Light
6. Montague Northeast Nuclear Energy
7. New Haven NY State Electric & Gas
8. Erie Ohio Edison
9. Pebble Springs Portland General Electric
10. Clinch River Project Management Corp. /TVA
11. Black Fox Public Service of Oklahoma
12. Skagit Puget Sound Power & Light
13. Davis Besse 2/3 Toledo Edison
14. Haven Wisconsin Electric Power
15. Greene County Power Authority of the State of NY
16. FNP Offshore Power
CONSTRUCTION PERMIT APPLICATION
Pressurized Water Reactors
50-452/453
50-471
50-488/489/490
50-500/501
50-502
50-514/515
50-568/569
50-580/581
50-596/597
50-537
50-549
50-437
CONSTRUCTION PERMIT APPLICATION
Boiling Water Reactors
50-466
50-496/497
50-522/523
50-556/557
Page Last Reviewed/Updated Tuesday, March 09, 2021