IE Circular No. 79-13 - Replacement of Diesel Fire Pump Starting Contactors
CR79013 July 6, 1979 MEMORANDUM FOR: B. H. Grier, Director, Region I J. P. O'Reilly, Director, Region II J. G. Keppler, Director, Region III K. V. Seyfrit, Director, Region IV R. H. Engelken, Director, Region V FROM: Norman C. Moseley, Director, Division of Reactor Operations Inspections, IE SUBJECT: IE Circular No. 79-13 - REPLACEMENT OF DIESEL FIRE PUMP STARTING CONTACTORS The subject Circular is transmitted for issuance on July 13, 1979. The Circular should be issued to all power reactor operating facilities and all utilities having a construction permit. The text of the Circular and draft letter to the licensees and permit holders are enclosed for this purpose. Norman C. Moseley, Director Division of Reactor Operations Inspection Office of Inspection and Enforcement Enclosures: 1. Draft Transmittal Letter 2. IE Circular No. 79-13 CONTACT: V. D. Thomas, IE 49-28180 . (Draft transmittal letter for IE Circular 79-13, to each holder of an Operating License or a Construction Permit.) IE Circular No. 79-13 Addressee: The enclosed IE Circular No. 79-13, is forwarded to you for information. No written response is required. Should you have any questions related to your understanding of this matter, please contact this office. Sincerely, Signature (Regional Director) Enclosures: 1. IE Circular No. 79-13 2. List of IE Circulars Issued in the Last 12 Months . UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C. 20555 July 10, 1979 IE Circular No. 79-13 REPLACEMENT OF DIESEL FIRE PUMP STARTING CONTACTORS Description of Circumstances: On May 28, 1978, the Diesel Fire Pump failed to start remotely at Davis-Besse, Unit 1 facility operated by Toledo Edison Company. The cause for failure was defective starting contactors. A subsequent investigation into the cause of a similar failure on January 18, 1978, at Commonwealth Edison Company's Dresden 2/3 Diesel Fire Pump identified a generic problem with Cummins Industrial Fire Pump Engines. Discussion: The investigation revealed that Cummins Engine Company issued a Service/Parts Topics No. 74T 13-3A announcing new components available for Industrial Fire Pumps (NH-220-IF, N-855-F, N-855-F1, NT-855-F2 series engines) to improve operation of inline 6 cylinder Industrial Fire Pump Engines. In this topic, Cummins recommends that when replacing the 118848 magnetic switch and 199573 DC relay contactor, use the new 217588 magnetic switch. The new design component has a 6 ampere draw whereas the old combination has approximately 3 amperes draw. Davis Besse and Dresden sites have implemented the corrective action recommended by Cummins. Recommended Actions for Licensees' Consideration: All holders of operating licenses or construction permits should be aware of the potential problem of the type discussed above. Because of the generic implications in this matter, it is recommended that both licensees of operating facilities and holders of construction permits conduct a review to determine if the above diesel fire pump engines are in use or planned for use at your facility(ies). If these engines are in use or planned for use, determine if the Cummins type 118848 Magnetic Switch and 199573 DC relay contactors are also employed. For those engines which have these components, develop a program for their replacement with the new 217588 Magnetic Switch. No written response to this Circular is required. If you require additional information regarding these matters, contact the Director of the appropriate NRC Regional Office. Enclosure: Cummins Service/Parts Topics No. 74 T 13-3A
Page Last Reviewed/Updated Tuesday, March 09, 2021
Page Last Reviewed/Updated Tuesday, March 09, 2021