Power Reactor Status Report for May 16, 2020

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Beaver Valley 1 41 Decreasing power for Feedwater Reg Valve Repair *
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 100
Ginna 0 2020-04-05 REFUELING OUTAGE
Hope Creek 1 100
Indian Point 2 0 2020-04-30 SHUTDOWN FOR PERMANENT DEFUELING
Indian Point 3 100
Limerick 1 100
Limerick 2 100
Millstone 2 0 2020-04-23 REFUELING OUTAGE *
Millstone 3 100
Nine Mile Point 1 100
Nine Mile Point 2 100
Peach Bottom 2 100
Peach Bottom 3 100
Salem 1 100
Salem 2 0 2020-05-14 Shutdown For Maintenance
Seabrook 1 100 Less than 1100 MW Net if Automatic Voltage Regulator non-functional. *
Susquehanna 1 82 Reduced Power For Rod Pattern Adjustment *
Susquehanna 2 100 MAINTAIN 100 MVAR DUE TO GRID INSTABILITIES
Three Mile Island 1 0 2019-09-20 Reactor defueled for permanent shutdown

Region 2

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Browns Ferry 1 100
Browns Ferry 2 100
Browns Ferry 3 100
Brunswick 1 100
Brunswick 2 100
Catawba 1 0 2020-05-01 REFUELING OUTAGE
Catawba 2 100
Farley 1 100
Farley 2 100
Harris 1 100
Hatch 1 100
Hatch 2 100
McGuire 1 100
McGuire 2 100
North Anna 1 100
North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 100
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100
Sequoyah 1 14 Not synced *
Sequoyah 2 100
Summer 100 *
Surry 1 100
Surry 2 0 2020-05-02 REFUELING OUTAGE
Turkey Point 3 100
Turkey Point 4 100
Vogtle 1 100
Vogtle 2 100
Watts Bar 1 0 2020-05-08 Refueling Outage
Watts Bar 2 0 2020-05-15 Reduced Power For Planned Maintenance *

Region 3

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 100
Byron 2 100
Clinton 99 100% ELECTRICAL CAPABILITY
D.C. Cook 1 100 High System Voltage Action
D.C. Cook 2 100 High System Voltage Action
Davis-Besse 100 HIGH SYSTEM VOLTAGE ACTION *
Dresden 2 100
Dresden 3 100
Duane Arnold 96 Holding power for rod pattern adjustment
Fermi 2 0 2020-03-21 REFUELING OUTAGE
LaSalle 1 100
LaSalle 2 100
Monticello 100
Palisades 100
Perry 1 100
Point Beach 1 100
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 100
Quad Cities 2 100

Region 4

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 100
Callaway 100
Columbia Generating Station 100
Comanche Peak 1 100
Comanche Peak 2 100 *
Cooper 100
Diablo Canyon 1 52 Reduced Power For Planned Maintenance
Diablo Canyon 2 100
Grand Gulf 1 0 2020-02-22 REFUELING OUTAGE
Palo Verde 1 100
Palo Verde 2 100
Palo Verde 3 100
River Bend Station 1 100
South Texas 1 100
South Texas 2 100
Waterford 3 100
Wolf Creek 1 100

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.