Power Reactor Status Report for November 11, 2013
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 48 | CONDENSATE PUMP MOTOR REPLACEMENT | |||
| Beaver Valley 2 | 100 | ||||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 56 | REDUCING POWER TO 50% TO INVESTIGATE TUBE LEAK | * | ||
| Ginna | 100 | ||||
| Hope Creek 1 | 36 | HOLDING POWER PENDING RESOLUTION OF RECIRC PUMP CONTROLLER ISSUE | * | ||
| Indian Point 2 | 100 | 13.8 KV LINE 33332LM OOS | |||
| Indian Point 3 | 100 | 13.8 KV LINE 33332LM OOS | |||
| Limerick 1 | 100 | ||||
| Limerick 2 | 100 | ||||
| Millstone 2 | 0 | 11/09/2013 | FORCED OUTAGE - RX TRIP DUE TO LOSS OF CONDENSER VACUUM - SEE EN #49525 - RESTART ANTICIPATED WITHIN THE NEXT 24 HOURS | * | |
| Millstone 3 | 93 | HEATER DRAIN PUMP MAINTENANCE COMPLETED - WILL INCREASE POWER SHORTLY | * | ||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 100 | ||||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 100 | 345 KV LINE 342 OUT OF SERVICE | |||
| Salem 1 | 100 | ||||
| Salem 2 | 100 | ||||
| Seabrook 1 | 100 | ONE CONTINGENCY AWAY FROM DOWN POWER TO 800MW DUE TO LINE OUTAGE | |||
| Susquehanna 1 | 59 | MAINTAINING POWER <60% DUE TO TEMPERATURE LIMITATIONS RELATED TO THE TURBINE BUILDING CHILLERS - HIGH SYSTEM VOLTAGE ACTION IN EFFECT | * | ||
| Susquehanna 2 | 100 | HIGH SYSTEM VOLTAGE ACTION IN EFFECT | * | ||
| Three Mile Island 1 | 0 | 10/27/2013 | REFUELING OUTAGE - HIGH SYSTEM VOLTAGE ACTION IN EFFECT | * | |
| Vermont Yankee | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 100 | ||||
| Browns Ferry 2 | 100 | ||||
| Browns Ferry 3 | 100 | ||||
| Brunswick 1 | 100 | ||||
| Brunswick 2 | 100 | ||||
| Catawba 1 | 100 | * | |||
| Catawba 2 | 100 | ||||
| Farley 1 | 100 | ||||
| Farley 2 | 100 | ||||
| Harris 1 | 0 | 11/08/2013 | REFUELING OUTAGE - RCS DEPRESSURIZED | * | |
| Hatch 1 | 100 | ||||
| Hatch 2 | 100 | ||||
| McGuire 1 | 100 | ||||
| McGuire 2 | 98 | FORMER 100% NOW 98% BECAUSE OF POWER UPRATE | |||
| North Anna 1 | 100 | ||||
| North Anna 2 | 100 | ||||
| Oconee 1 | 20 | REDUCED POWER TO INVESTIGATE RCS LEAKAGE | * | ||
| Oconee 2 | 0 | 10/11/2013 | REFUELING OUTAGE | ||
| Oconee 3 | 100 | ||||
| Robinson 2 | 91 | HOLDING POWER FOR REQUIRED SURVEILLANCIES | * | ||
| Saint Lucie 1 | 54 | INCREASING POWER TO 100% | * | ||
| Saint Lucie 2 | 100 | ||||
| Sequoyah 1 | 0 | 10/14/2013 | REFUELING OUTAGE | * | |
| Sequoyah 2 | 100 | ||||
| Summer | 100 | ||||
| Surry 1 | 0 | 10/19/2013 | CORE RELOADED | ||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 100 | ||||
| Vogtle 2 | 100 | ||||
| Watts Bar 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | ||||
| Byron 2 | 100 | ||||
| Clinton | 97 | 100% ELECTRICAL CAPABILITY | |||
| D.C. Cook 1 | 100 | ||||
| D.C. Cook 2 | 0 | 10/01/2013 | REFUELING OUTAGE | ||
| Davis-Besse | 100 | ||||
| Dresden 2 | 0 | 11/10/2013 | REFUELING OUTAGE | * | |
| Dresden 3 | 100 | ||||
| Duane Arnold | 98 | REDUCED POWER PER LOAD DISPATCHER INSTRUCTIONS | |||
| Fermi 2 | 100 | * | |||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 100 | ||||
| Palisades | 100 | ||||
| Perry 1 | 100 | ||||
| Point Beach 1 | 100 | ||||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | ||||
| Prairie Island 2 | 0 | 09/21/2013 | REFUELING OUTAGE | ||
| Quad Cities 1 | 100 | ||||
| Quad Cities 2 | 90 | REDUCED POWER FOR ROD PATTERN ADJUSTMENT | * |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | ||||
| Comanche Peak 1 | 100 | ||||
| Comanche Peak 2 | 100 | ||||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 100 | ||||
| Diablo Canyon 2 | 100 | ||||
| Fort Calhoun | 0 | 04/09/2011 | MAINTENANCE OUTAGE | ||
| Grand Gulf 1 | 100 | ||||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 0 | 10/04/2013 | REFUELING OUTAGE | ||
| River Bend 1 | 100 | ||||
| South Texas 1 | 100 | ||||
| South Texas 2 | 100 | ||||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 100 |