Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for November 11, 2013

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 48   CONDENSATE PUMP MOTOR REPLACEMENT    
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 56   REDUCING POWER TO 50% TO INVESTIGATE TUBE LEAK *  
Ginna 100        
Hope Creek 1 36   HOLDING POWER PENDING RESOLUTION OF RECIRC PUMP CONTROLLER ISSUE *  
Indian Point 2 100   13.8 KV LINE 33332LM OOS    
Indian Point 3 100   13.8 KV LINE 33332LM OOS    
Limerick 1 100        
Limerick 2 100        
Millstone 2 0 11/09/2013 FORCED OUTAGE - RX TRIP DUE TO LOSS OF CONDENSER VACUUM - SEE EN #49525 - RESTART ANTICIPATED WITHIN THE NEXT 24 HOURS *  
Millstone 3 93   HEATER DRAIN PUMP MAINTENANCE COMPLETED - WILL INCREASE POWER SHORTLY *  
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100   345 KV LINE 342 OUT OF SERVICE    
Salem 1 100        
Salem 2 100        
Seabrook 1 100   ONE CONTINGENCY AWAY FROM DOWN POWER TO 800MW DUE TO LINE OUTAGE    
Susquehanna 1 59   MAINTAINING POWER <60% DUE TO TEMPERATURE LIMITATIONS RELATED TO THE TURBINE BUILDING CHILLERS - HIGH SYSTEM VOLTAGE ACTION IN EFFECT *  
Susquehanna 2 100   HIGH SYSTEM VOLTAGE ACTION IN EFFECT *  
Three Mile Island 1 0 10/27/2013 REFUELING OUTAGE - HIGH SYSTEM VOLTAGE ACTION IN EFFECT *  
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100     *  
Catawba 2 100        
Farley 1 100        
Farley 2 100        
Harris 1 0 11/08/2013 REFUELING OUTAGE - RCS DEPRESSURIZED *  
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 98   FORMER 100% NOW 98% BECAUSE OF POWER UPRATE    
North Anna 1 100        
North Anna 2 100        
Oconee 1 20   REDUCED POWER TO INVESTIGATE RCS LEAKAGE *  
Oconee 2 0 10/11/2013 REFUELING OUTAGE    
Oconee 3 100        
Robinson 2 91   HOLDING POWER FOR REQUIRED SURVEILLANCIES *  
Saint Lucie 1 54   INCREASING POWER TO 100% *  
Saint Lucie 2 100        
Sequoyah 1 0 10/14/2013 REFUELING OUTAGE *  
Sequoyah 2 100        
Summer 100        
Surry 1 0 10/19/2013 CORE RELOADED    
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 0 10/01/2013 REFUELING OUTAGE    
Davis-Besse 100        
Dresden 2 0 11/10/2013 REFUELING OUTAGE *  
Dresden 3 100        
Duane Arnold 98   REDUCED POWER PER LOAD DISPATCHER INSTRUCTIONS    
Fermi 2 100     *  
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 0 09/21/2013 REFUELING OUTAGE    
Quad Cities 1 100        
Quad Cities 2 90   REDUCED POWER FOR ROD PATTERN ADJUSTMENT *  

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 0 04/09/2011 MAINTENANCE OUTAGE    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 0 10/04/2013 REFUELING OUTAGE    
River Bend 1 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        