| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 0 | 09/29/2013 | REFUELING OUTAGE - CORE RELOAD COMPLETE | ||
| Beaver Valley 2 | 100 | ||||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 100 | ||||
| Ginna | 100 | ||||
| Hope Creek 1 | 0 | 10/11/2013 | REFUELING OUTAGE | ||
| Indian Point 2 | 100 | 13.8 KV LINE 33332LM OOS 345 KV OUTPUT BREAKER OPEN | |||
| Indian Point 3 | 100 | 13.8 KV LINE 33332LM OOS | |||
| Limerick 1 | 100 | ||||
| Limerick 2 | 100 | ||||
| Millstone 2 | 100 | ||||
| Millstone 3 | 100 | ||||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 100 | ||||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 23 | HOLDING POWER FOR TESTING | * | ||
| Pilgrim 1 | 100 | ||||
| Salem 1 | 100 | ||||
| Salem 2 | 100 | ||||
| Seabrook 1 | 100 | ONE CONTINGENCY AWAY FROM DOWN POWER TO 800MW DUE TO LINE OUTAGE | |||
| Susquehanna 1 | 99 | 100% ELECTRICAL CAPABILITY | |||
| Susquehanna 2 | 96 | INCREASING POWER | * | ||
| Three Mile Island 1 | 100 | * | |||
| Vermont Yankee | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 100 | ||||
| Browns Ferry 2 | 100 | ||||
| Browns Ferry 3 | 100 | ||||
| Brunswick 1 | 100 | ||||
| Brunswick 2 | 100 | ||||
| Catawba 1 | 100 | ||||
| Catawba 2 | 100 | * | |||
| Farley 1 | 0 | 09/29/2013 | PREPARING FOR STARTUP | * | |
| Farley 2 | 100 | ||||
| Harris 1 | 100 | ||||
| Hatch 1 | 4 | STARTUP IN PROGRESS | * | ||
| Hatch 2 | 100 | ||||
| McGuire 1 | 100 | ||||
| McGuire 2 | 100 | ||||
| North Anna 1 | 100 | ||||
| North Anna 2 | 100 | ||||
| Oconee 1 | 100 | ||||
| Oconee 2 | 0 | 10/11/2013 | REFUELING OUTAGE DEFUELED | ||
| Oconee 3 | 0 | 10/24/2013 | MANUAL REACTOR TRIP FOLLOWING FEEDWATER OSCILLATIONS | * | 1 |
| Robinson 2 | 0 | 09/13/2013 | REFUELING OUTAGE | * | |
| Saint Lucie 1 | 0 | 09/30/2013 | REFUELING OUTAGE - CORE RELOAD COMPLETE | ||
| Saint Lucie 2 | 100 | ||||
| Sequoyah 1 | 0 | 10/14/2013 | REFUELING OUTAGE DEFUELED | ||
| Sequoyah 2 | 100 | ||||
| Summer | 100 | ||||
| Surry 1 | 0 | 10/19/2013 | REFUELING OUTAGE | ||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 100 | ||||
| Vogtle 2 | 24 | MAIN GENERATOR TRIP SHORTLY AFTER SYNCING TO GRID. INVESTIGATION IN PROGRESS | * | ||
| Watts Bar 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | ||||
| Byron 2 | 100 | ||||
| Clinton | 0 | 10/07/2013 | REFUELING OUTAGE | ||
| D.C. Cook 1 | 100 | ||||
| D.C. Cook 2 | 0 | 10/01/2013 | REFUELING OUTAGE | * | |
| Davis-Besse | 100 | ||||
| Dresden 2 | 95 | COASTDOWN TO REFUELING OUTAGE | |||
| Dresden 3 | 2 | STARTUP IN PROGRESS | * | ||
| Duane Arnold | 100 | ||||
| Fermi 2 | 100 | ||||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 100 | ||||
| Palisades | 100 | ||||
| Perry 1 | 100 | ||||
| Point Beach 1 | 100 | ||||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | ||||
| Prairie Island 2 | 0 | 09/21/2013 | DEFUELED | ||
| Quad Cities 1 | 100 | ||||
| Quad Cities 2 | 100 |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | ||||
| Comanche Peak 1 | 100 | ||||
| Comanche Peak 2 | 100 | ||||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 100 | ||||
| Diablo Canyon 2 | 100 | ||||
| Fort Calhoun | 0 | 04/09/2011 | EXTENDED OUTAGE | ||
| Grand Gulf 1 | 100 | ||||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 0 | 10/04/2013 | REFUELING OUTAGE | ||
| River Bend 1 | 100 | ||||
| South Texas 1 | 100 | ||||
| South Texas 2 | 100 | ||||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 0 | 10/18/2013 | TECH SPEC REQUIRED SHUTDOWN. SEE EN #49448. |