Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 82   SCHEDULED WATER BOX CLEANING    
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 25   INCREASING POWER; 138 KV FEEDER (LINES 33332) OOS *  
Indian Point 3 100   138 KV FEEDER (LINE 33332LM) OOS    
Limerick 1 92   TURBINE VALVE TESTING *  
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 30   INCREASING POWER *  
Salem 1 100        
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 94   INCREASING POWER *  
Susquehanna 2 93   INCREASING POWER *  
Three Mile Island 1 100        
Vermont Yankee 98   COASTDOWN TO REFUELING OUTAGE    

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 93   COASTDOWN TO REFUELING OUTAGE    
Browns Ferry 3 0 02/11/2013 PLANNED MAINTENANCE OUTAGE    
Brunswick 1 98   ROD IMPROVEMENTS *  
Brunswick 2 97   COASTDOWN TO REFUELING OUTAGE    
Catawba 1 100        
Catawba 2 100        
Crystal River 3 0 02/03/2013 DEFUELED    
Farley 1 100        
Farley 2 100        
Harris 1 99   SECURING A HEATER DRAIN PUMP FOR CONTROLLER MAINTENANCE *  
Hatch 1 0 02/10/2013 FORCED OUTAGE SEE EVENT #43738    
Hatch 2 0 02/11/2013 REFUELING OUTAGE    
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 50   SCHEDULED DOWNPOWER TO REPAIR TURBINE GOVERNOR VALVE *  
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 65   INCREASING POWER *  
Turkey Point 4 0 11/04/2012 REFUELING OUTAGE    
Vogtle 1 100        
Vogtle 2 98   COASTDOWN TO REFUELING OUTAGE    
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 91   345 KV TRANSMISSION LINE WORK    
D.C. Cook 1 100        
D.C. Cook 2 99     *  
Davis-Besse 100        
Dresden 2 100        
Dresden 3 100        
Duane Arnold 100        
Fermi 2 67   MAIN FEEDPUMP REPAIRS IN PROGRESS    
Kewaunee 100        
La Salle 1 100        
La Salle 2 0 02/10/2013 REFUELING OUTAGE *  
Monticello 100        
Palisades 0 02/15/2013 TECH SPEC REQUIRED SHUTDOWN - SEE EN #48758 *  
Perry 1 97   COASTDOWN TO REFUELING OUTAGE    
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100   CCW LEAK IN CONTAINMENT    
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 0 02/02/2013 REFUELING OUTAGE - DEFUELED    
Fort Calhoun 0 04/09/2011 REFUELING OUTAGE -DEFUELED    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 0 01/09/2012 REFUELING OUTAGE    
San Onofre 3 0 01/31/2012 DEFUELED - FORCED OUTAGE - S/G REPAIR    
South Texas 1 100        
South Texas 2 0 01/08/2013 FORCED OUTAGE    
Waterford 3 100        
Wolf Creek 1 0 02/03/2013 REFUELING OUTAGE - FUEL OFFLOAD ON HOLD TO FIX FUEL TRANSFER SYSTEM    