United States Nuclear Regulatory Commission - Protecting People and the Environment
Home > NRC Library > Document Collections > Reports Associated with Events > Power Reactor Status Reports > 2008 > September 27

Power Reactor Status Report for September 27, 2008

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 0 09/14/2008 REFUELING OUTAGE    
Ginna 100        
Hope Creek 1 76   REDUCED POWER FOR TURBINE VALVE TESTING, FEEDWATER HEATER REPAIR WORK AND CONTROL ROD EXCHANGE *  
Indian Point 2 100     *  
Indian Point 3 100     *  
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 98   COASTDOWN TO REFUELING OUTAGE    
Peach Bottom 2 0 09/14/2008 REFUELING OUTAGE    
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 94   100% ELECTRICAL CAPABILITY    
Susquehanna 2 100        
Three Mile Island 1 100        
Vermont Yankee 90   LINE 381 (345 KV) OOS WITH POWER REDUCED TO MAINTAIN STABILITY. *  

Region 2

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100   ONE COOLING TOWER TRANSFORMER OOS *  
Browns Ferry 2 100   ONE COOLING TOWER TRANSFORMER OOS *  
Browns Ferry 3 100   ONE COOLING TOWER TRANSFORMER OOS *  
Brunswick 1 100        
Brunswick 2 100     *  
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 0 09/20/2008 SHUTDOWN FOR REFUELING OUTAGE    
McGuire 2 100        
North Anna 1 100        
North Anna 2 0 09/13/2008 DEFUELED    
Oconee 1 100        
Oconee 2 19   REDUCED POWER DUE TO MAIN TRANSFORMER OIL LEAK. TG OFFLINE.    
Oconee 3 100        
Robinson 2 0 09/25/2008 REFUELING OUTAGE - RCS COOLDOWN IN PROGRESS *  
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 0 09/14/2008 REFUELING OUTAGE    
Watts Bar 1 99   INCREASING POWER. *  

Region 3

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY *  
D.C. Cook 1 0 09/20/2008 SEE EN #44507. *  
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 0 09/24/2008 FORCED MAINTENANCE OUTAGE. *  
Dresden 3 95   COASTDOWN TO REFUELING OUTAGE    
Duane Arnold 98   100% ELECTRICAL CAPABILITY    
Fermi 2 100     *  
Kewaunee 100        
La Salle 1 100        
La Salle 2 60   POWER SUPPRESSION TESTING *  
Monticello 1   STARTUP IN PROGRESS REACTOR SUBCRITICAL *  
Palisades 100        
Perry 1 100        
Point Beach 1 98   ADMINISTRATIVE RESTRICTION *  
Point Beach 2 98   ADMINISTRATIVE RESTRICTION *  
Prairie Island 1 100        
Prairie Island 2 0 09/19/2008 REFUELING OUTAGE    
Quad Cities 1 98   100% ELECTRICAL CAPABILITY    
Quad Cities 2 97   100% ELECTRICAL CAPABILITY    

Region 4

To top of page
Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 91   COASTDOWN TO REFUELING OUTAGE *  
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 0 09/21/2008 REFUELING OUTAGE. RPV HEAD REMOVED.    
Palo Verde 1 100        
Palo Verde 2 99   HIGH RATE BLOWDOWN *  
Palo Verde 3 100        
River Bend 1 99   INCREASING POWER *  
San Onofre 2 99        
San Onofre 3 75   REDUCED POWER DUE TO LP EXTRACTION STEAM VALVE BELLOWS LEAK AND CONDENSER TUBE LEAK. MAINTENANCE ONGOING.    
South Texas 1 100        
South Texas 2 90   COASTDOWN TO REFUELING OUTAGE    
Waterford 3 100        
Wolf Creek 1 100        

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
Page Last Reviewed/Updated Thursday, March 29, 2012
Thursday, March 29, 2012