Power Reactor Status Report for September 21, 2008
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 100 | ||||
| Beaver Valley 2 | 25 | MAIN FEED REG VALVE MAINT | * | ||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 0 | 09/14/2008 | REFUELING OUTAGE | ||
| Ginna | 100 | ||||
| Hope Creek 1 | 100 | ||||
| Indian Point 2 | 100 | 1 OF 3 138 KV FEEDERS OOS | |||
| Indian Point 3 | 100 | 1 OF 3 138 KV FEEDERS OOS | |||
| Limerick 1 | 100 | MIN GEN ALERT | * | ||
| Limerick 2 | 100 | MIN GEN ALERT | * | ||
| Millstone 2 | 100 | ||||
| Millstone 3 | 100 | ||||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 100 | ||||
| Peach Bottom 2 | 0 | 09/14/2008 | REFUELING OUTAGE | ||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 100 | * | |||
| Salem 1 | 84 | EXCESS VOLTAGE GRID RESTRICTION | * | ||
| Salem 2 | 49 | EXCESS VOLTAGE GRID RESTRICTION | * | ||
| Seabrook 1 | 100 | * | |||
| Susquehanna 1 | 94 | 100% ELECTRICAL CAPABILITY MIN GEN ALERT | |||
| Susquehanna 2 | 70 | MIN GEN ALERT PLANT TESTING | * | ||
| Three Mile Island 1 | 100 | MIN GEN ALERT | |||
| Vermont Yankee | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 100 | ONE COOLING TOWER TRANSFORMER OOS. | |||
| Browns Ferry 2 | 0 | 09/17/2008 | ONE COOLING TOWER TRANSFORMER OOS. MAINTENANCE OUTAGE TO REPAIR GENERATOR HYDROGEN COOLER | ||
| Browns Ferry 3 | 100 | ONE COOLING TOWER TRANSFORMER OOS. | |||
| Brunswick 1 | 100 | ||||
| Brunswick 2 | 97 | * | |||
| Catawba 1 | 100 | ||||
| Catawba 2 | 100 | ||||
| Crystal River 3 | 100 | ||||
| Farley 1 | 100 | ||||
| Farley 2 | 100 | ||||
| Harris 1 | 100 | ||||
| Hatch 1 | 100 | ||||
| Hatch 2 | 100 | ||||
| McGuire 1 | 0 | 09/20/2008 | SHUTDOWN FOR REFUELING OUTAGE MODE 5 | * | |
| McGuire 2 | 100 | ||||
| North Anna 1 | 100 | ||||
| North Anna 2 | 0 | 09/13/2008 | REFUELING OUTAGE; CORE OFFLOAD IN PROGRESS | ||
| Oconee 1 | 100 | ||||
| Oconee 2 | 100 | ||||
| Oconee 3 | 100 | ||||
| Robinson 2 | 99 | * | |||
| Saint Lucie 1 | 100 | ||||
| Saint Lucie 2 | 100 | ||||
| Sequoyah 1 | 100 | ||||
| Sequoyah 2 | 100 | ||||
| Summer | 100 | ||||
| Surry 1 | 100 | ||||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 100 | ||||
| Vogtle 2 | 0 | 09/14/2008 | REFUELING OUTAGE | ||
| Watts Bar 1 | 0 | REACTOR TRIP. SEE EN #44506 | * | 1 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | MINIMUM GENERATION ALERT IN EFFECT UNTIL 0600 CDT ON 9/21/08 | * | ||
| Byron 2 | 100 | MINIMUM GENERATION ALERT IN EFFECT UNTIL 0600 CDT ON 9/21/08 | * | ||
| Clinton | 97 | 100% ELECTRICAL CAPABILITY | * | ||
| D.C. Cook 1 | 0 | 09/20/2008 | UNUSUAL EVENT DECLARED. SEE EN #44507. | * | 1 |
| D.C. Cook 2 | 100 | ||||
| Davis-Besse | 100 | ||||
| Dresden 2 | 99 | 100% ELECTRICAL CAPABILITY | |||
| Dresden 3 | 97 | COASTDOWN TO REFUELING OUTAGE | |||
| Duane Arnold | 98 | 100% ELECTRICAL CAPABILITY | |||
| Fermi 2 | 100 | DOUBLE CIRCUIT TOWER CONTINGENCY UNTIL 9/26. MINIMUM GENERATION ALERT IN EFFECT UNTIL 0900 CDT ON 9/21/08 | * | ||
| Kewaunee | 100 | ||||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 0 | 09/11/2008 | REACTOR SCRAM SEE EN # 44484. 2 R TRANSFORMER OUT OF SERVICE | * | |
| Palisades | 100 | ||||
| Perry 1 | 93 | INCREASING POWER | * | ||
| Point Beach 1 | 100 | * | |||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | ||||
| Prairie Island 2 | 0 | 09/19/2008 | REFUELING OUTAGE | * | |
| Quad Cities 1 | 98 | 100% ELECTRICAL CAPABILITY | |||
| Quad Cities 2 | 97 | 100% ELECTRICAL CAPABILITY |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | ||||
| Comanche Peak 1 | 96 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Comanche Peak 2 | 100 | ||||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 100 | ||||
| Diablo Canyon 2 | 100 | ||||
| Fort Calhoun | 100 | ||||
| Grand Gulf 1 | 97 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 20 | INCREASING POWER | * | ||
| River Bend 1 | 0 | 09/01/2008 | SEE EN# 44457. | ||
| San Onofre 2 | 99 | STEAM GENERATOR PRESSURE LIMITATION | |||
| San Onofre 3 | 75 | REDUCED POWER DUE TO LP EXTRACTION STEAM VALVE BELLOWS LEAK, HEATER DRAIN PUMP TRIP AND CONDENSER TUBE LEAK. | * | ||
| South Texas 1 | 100 | ||||
| South Texas 2 | 95 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 100 |