Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for March 30, 2008

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 0 03/28/2008 SHUTDOWN TO REPAIR SECONDARY STEAM LEAK    
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 0 03/23/2008 REFUELING OUTAGE *  
Indian Point 3 100   FEEDER 95891 OOS FOR SCHEDULED MAINTENANCE.    
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 0 03/21/2008 REFUELING OUTAGE    
Oyster Creek 92   HOLDING POWER FOR CONTROL VALVE OSCILLATION PROBLEM AND FEEDWATER HEATER ISSUES *  
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 93   500 KV LINE OOS FOR MAINTENANCE *  
Salem 2 0 03/11/2008 DEFUELED 500 KV LINE OOS FOR MAINTENANCE    
Seabrook 1 100        
Susquehanna 1 0 03/03/2008 REFUELING OUTAGE    
Susquehanna 2 100   VOLTAGE REGULATOR IN MANUAL    
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 100        
Browns Ferry 2 100        
Browns Ferry 3 0 03/18/2008 REFUELING OUTAGE    
Brunswick 1 0 03/14/2008 REFUELING OUTAGE    
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 92   INCREASING POWER *  
Hatch 2 100        
McGuire 1 100        
McGuire 2 0 03/01/2008 REFUELING OUTAGE    
North Anna 1 100        
North Anna 2 100        
Oconee 1 73   HOLDING POWER UNTIL OUTAGE; 1A1 RCP SHUT DOWN    
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 87   HOLDING POWER WHILE TROUBLESHOOTING SECONDARY CHEMISTRY ISSUE INVOLVING ONE CIRC WATER PUMP *  
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 50   HOLDING POWER PRIOR TO COMMENCING REFUELING OUTAGE *  
Vogtle 1 0 03/15/2008 DEFUELED    
Vogtle 2 98   100% ELECTRICAL CAPABILITY    
Watts Bar 1 80   HOLDING POWER FOR FUEL SOAK *  

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 0 03/23/2008 REFUELING OUTAGE    
Byron 2 100        
Clinton 96   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 0 03/25/2008 REFUELING OUTAGE    
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 98   100% ELECTRICAL CAPABILITY    
Dresden 3 98   100% ELECTRICAL CAPABILITY    
Duane Arnold 98   100% ELECTRICAL CAPABILITY    
Fermi 2 100        
Kewaunee 0 03/28/2008 SCHEDULED REFUELING OUTAGE *  
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100     *  
Quad Cities 1 97   100% ELECTRICAL OUTPUT    
Quad Cities 2 1   HEATUP INPROGRESS *  

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 0 03/16/2008 REFUELING OUTAGE    
Callaway 100        
Columbia Generating Station 65   LOWER POWER FOR MAINTENANCE ON 'B' REACTOR FEED TURBINE *  
Comanche Peak 1 100        
Comanche Peak 2 0 03/29/2008 REFUELING OUTAGE *  
Cooper 87   COASTDOWN TO REFUELING OUTAGE    
Diablo Canyon 1 100        
Diablo Canyon 2 0 02/03/2008 FUEL RELOAD IN PROGRESS    
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 0 03/28/2008 SCHEDULED REFUELING OUTAGE *  
Palo Verde 3 99   HIGH RATE BLOWDOWNS INPROGRESS *  
River Bend 1 100     *  
San Onofre 2 99        
San Onofre 3 100        
South Texas 1 0 03/29/2008 REFUELING OUTAGE *  
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 03/17/2008 REFUELING OUTAGE DEFUELED *  

Page Last Reviewed/Updated Thursday, March 25, 2021