Power Reactor Status Report for March 18, 2008
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Beaver Valley 1 | 100 | ||||
Beaver Valley 2 | 100 | ||||
Calvert Cliffs 1 | 100 | ||||
Calvert Cliffs 2 | 100 | ||||
FitzPatrick | 100 | * | |||
Ginna | 100 | ||||
Hope Creek 1 | 100 | OFFSITE LINE 5023 (500 KV) OOS | |||
Indian Point 2 | 98 | COASTDOWN TO REFUELING OUTAGE LINE 13W93 OOS | * | ||
Indian Point 3 | 100 | LINE 13W93 OOS | * | ||
Limerick 1 | 0 | 02/29/2008 | REFUELING OUTAGE | * | |
Limerick 2 | 100 | ||||
Millstone 2 | 100 | ||||
Millstone 3 | 100 | LINE 348 (345 KV) OOS UNTIL 3/21 | |||
Nine Mile Point 1 | 100 | ||||
Nine Mile Point 2 | 100 | ||||
Oyster Creek | 93 | HOLDING POWER FOR CONTROL VALVE OSCILLATION PROBLEM AND FEEDWATER HEATER ISSUES | * | ||
Peach Bottom 2 | 100 | ||||
Peach Bottom 3 | 100 | ||||
Pilgrim 1 | 100 | ||||
Salem 1 | 100 | ||||
Salem 2 | 0 | 03/11/2008 | REFUELING OUTAGE DEFUELED | * | |
Seabrook 1 | 100 | 369 KV NEWINGTON LINE OOS FROM 1300-1500 | * | ||
Susquehanna 1 | 0 | 03/03/2008 | REFUELING OUTAGE | ||
Susquehanna 2 | 100 | VOLTAGE REGULATOR IN MANUAL | |||
Three Mile Island 1 | 100 | ||||
Vermont Yankee | 100 |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Browns Ferry 1 | 100 | ||||
Browns Ferry 2 | 100 | ||||
Browns Ferry 3 | 31 | COMMENCE REFUELING OUTAGE AT 0900 | * | ||
Brunswick 1 | 0 | 03/14/2008 | REFUELING OUTAGE | * | |
Brunswick 2 | 100 | ||||
Catawba 1 | 100 | ||||
Catawba 2 | 100 | ||||
Crystal River 3 | 0 | 03/01/2008 | DROP LINE WELD REPAIR IN PROGRESS | ||
Farley 1 | 100 | ||||
Farley 2 | 100 | ||||
Harris 1 | 100 | ||||
Hatch 1 | 0 | 03/14/2008 | MAINTENANCE OUTAGE | ||
Hatch 2 | 100 | ||||
McGuire 1 | 100 | ||||
McGuire 2 | 0 | 03/01/2008 | DEFUELED | ||
North Anna 1 | 100 | ||||
North Anna 2 | 100 | ||||
Oconee 1 | 73 | 1A1 RCP SHUT DOWN | |||
Oconee 2 | 100 | ||||
Oconee 3 | 100 | ||||
Robinson 2 | 100 | ||||
Saint Lucie 1 | 100 | ||||
Saint Lucie 2 | 100 | ||||
Sequoyah 1 | 100 | 161 KV MOCCASIN LINE OOS THRU 3/21 | |||
Sequoyah 2 | 100 | 161 KV MOCCASIN LINE OOS THRU 3/21 | |||
Summer | 100 | ||||
Surry 1 | 100 | ||||
Surry 2 | 100 | ||||
Turkey Point 3 | 100 | ||||
Turkey Point 4 | 100 | ||||
Vogtle 1 | 0 | 03/15/2008 | REFUELING OUTAGE | * | |
Vogtle 2 | 99 | 100% ELECTRICAL CAPABILITY | * | ||
Watts Bar 1 | 0 | 02/10/2008 | REFUELING OUTAGE |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Braidwood 1 | 100 | ||||
Braidwood 2 | 100 | ||||
Byron 1 | 100 | ||||
Byron 2 | 100 | ||||
Clinton | 96 | 100% ELECTRICAL CAPABILITY | |||
D.C. Cook 1 | 100 | ||||
D.C. Cook 2 | 100 | ||||
Davis-Besse | 100 | ||||
Dresden 2 | 99 | 100% ELECTRICAL CAPABILITY; LINE 1221 (345KV) OOS WITH SWITCHING ONGOING UNTIL 3/18 | * | ||
Dresden 3 | 98 | 100% ELECTRICAL CAPABILITY | |||
Duane Arnold | 98 | 100% ELECTRICAL CAPABILITY | * | ||
Fermi 2 | 100 | SHOAL LINE (120KV) OOS UNTIL 3/20 (1 OF 5) | * | ||
Kewaunee | 100 | ||||
La Salle 1 | 100 | ||||
La Salle 2 | 100 | ||||
Monticello | 100 | ||||
Palisades | 100 | ||||
Perry 1 | 60 | POWER SUPPRESSION TESTING AND ROD SEQUENCE EXCHANGE | * | ||
Point Beach 1 | 100 | ||||
Point Beach 2 | 100 | ||||
Prairie Island 1 | 0 | 03/16/2008 | REFUELING OUTAGE | ||
Prairie Island 2 | 100 | ||||
Quad Cities 1 | 97 | 100% ELECTRICAL OUTPUT | |||
Quad Cities 2 | 0 | 03/02/2008 | REFUELING OUTAGE |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
---|---|---|---|---|---|
Arkansas Nuclear 1 | 100 | ||||
Arkansas Nuclear 2 | 0 | 03/16/2008 | REFUELING OUTAGE | ||
Callaway | 100 | ||||
Columbia Generating Station | 100 | ||||
Comanche Peak 1 | 100 | ||||
Comanche Peak 2 | 45 | INCREASING POWER | * | ||
Cooper | 90 | COASTDOWN TO REFUELING OUTAGE | |||
Diablo Canyon 1 | 100 | DIABLO-MESA 230 KV LINE OOS 3/11 THRU 3/18. DIABLO-GATES1 500 KV LINE OOS THRU 3/28 | |||
Diablo Canyon 2 | 0 | 02/03/2008 | DEFUELED | ||
Fort Calhoun | 0 | 03/15/2008 | TRIP SEE EN# 44066 | ||
Grand Gulf 1 | 100 | ||||
Palo Verde 1 | 100 | ||||
Palo Verde 2 | 100 | ||||
Palo Verde 3 | 100 | ||||
River Bend 1 | 70 | TROUBLESHOOT FEEDWATER HEATER FLOW ISSUE | * | ||
San Onofre 2 | 99 | ||||
San Onofre 3 | 100 | ||||
South Texas 1 | 89 | COASTDOWN TO REFUELING OUTAGE | |||
South Texas 2 | 100 | ||||
Waterford 3 | 100 | ||||
Wolf Creek 1 | 0 | 03/17/2008 | TRIP - SEE EN #44072 | * |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021