Power Reactor Status Report for February 3, 2008
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 100 | ||||
| Beaver Valley 2 | 100 | ||||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 100 | ||||
| Ginna | 100 | ||||
| Hope Creek 1 | 100 | * | |||
| Indian Point 2 | 100 | ||||
| Indian Point 3 | 100 | ||||
| Limerick 1 | 97 | COASTDOWN TO REFUELING OUTAGE | |||
| Limerick 2 | 0 | 02/01/2008 | TRANSFORMER MAINTENANCE OUTAGE | * | |
| Millstone 2 | 100 | ||||
| Millstone 3 | 100 | ||||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 92 | HOLDING POWER FOR TURBINE VALVE ISSUES | |||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 69 | PLANNED LOAD DROP | * | ||
| Pilgrim 1 | 100 | ||||
| Salem 1 | 100 | ||||
| Salem 2 | 100 | ||||
| Seabrook 1 | 100 | ||||
| Susquehanna 1 | 85 | ROD PATTERN ADJUSTMENT | * | ||
| Susquehanna 2 | 100 | VOLTAGE REGULATOR IN MANUAL | |||
| Three Mile Island 1 | 100 | ||||
| Vermont Yankee | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 100 | ||||
| Browns Ferry 2 | 100 | ||||
| Browns Ferry 3 | 100 | ||||
| Brunswick 1 | 99 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Brunswick 2 | 100 | ||||
| Catawba 1 | 100 | ||||
| Catawba 2 | 100 | ||||
| Crystal River 3 | 100 | ||||
| Farley 1 | 100 | ||||
| Farley 2 | 100 | ||||
| Harris 1 | 100 | ||||
| Hatch 1 | 90 | COASTDOWN TO REFUELING OUTAGE CONDENSATE PUMP TRIP | |||
| Hatch 2 | 100 | ||||
| McGuire 1 | 100 | ||||
| McGuire 2 | 100 | ||||
| North Anna 1 | 100 | ||||
| North Anna 2 | 0 | 02/01/2008 | RCP MAINTENANCE | * | |
| Oconee 1 | 100 | ||||
| Oconee 2 | 100 | ||||
| Oconee 3 | 100 | ||||
| Robinson 2 | 100 | ||||
| Saint Lucie 1 | 100 | ||||
| Saint Lucie 2 | 0 | 01/29/2008 | MAINTENANCE ON RCPS | * | |
| Sequoyah 1 | 100 | ||||
| Sequoyah 2 | 100 | ||||
| Summer | 100 | * | |||
| Surry 1 | 100 | ||||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 98 | 100% ELECTRICAL CAPABILITY | |||
| Vogtle 2 | 98 | 100% ELECTRICAL CAPABILITY | |||
| Watts Bar 1 | 100 | * |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | * | |||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | ||||
| Byron 2 | 100 | ||||
| Clinton | 0 | 01/11/2008 | REFUELING OUTAGE | ||
| D.C. Cook 1 | 0 | 02/02/2008 | REACTOR TRIP - SEE EN #43956 | * | 1 |
| D.C. Cook 2 | 100 | ||||
| Davis-Besse | 18 | HOLDING POWER | * | ||
| Dresden 2 | 89 | SCHEDULED ROD RECOVERY | * | ||
| Dresden 3 | 97 | 100% ELECTRICAL CAPABILITY | |||
| Duane Arnold | 98 | 100% ELECTRICAL CAPABILITY. | |||
| Fermi 2 | 5 | REACTOR START UP IN-PROGRESS | * | ||
| Kewaunee | 100 | ||||
| La Salle 1 | 76 | COASTDOWN TO REFUELING OUTAGE | * | ||
| La Salle 2 | 100 | ||||
| Monticello | 99 | LOWERED POWER DUE TO FEED REG VALVE LOCKUP | * | ||
| Palisades | 100 | ||||
| Perry 1 | 100 | ||||
| Point Beach 1 | 0 | 01/16/2008 | EXITING OUTAGE | * | |
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 92 | COASTDOWN TO REFUELING OUTAGE | * | ||
| Prairie Island 2 | 100 | ||||
| Quad Cities 1 | 34 | TUBE PLUGGING REPAIR - MAIN CONDENSER | * | ||
| Quad Cities 2 | 96 | 100% ELECTRICAL CAPABILITY |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | RECIRC PUMPS IN MANUAL | |||
| Comanche Peak 1 | 0 | 02/01/2008 | SCHEDULED MAINTENANCE | * | |
| Comanche Peak 2 | 100 | ||||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 100 | * | |||
| Diablo Canyon 2 | 30 | SHUTTING DOWN FOR REFUELING OUTAGE | * | ||
| Fort Calhoun | 100 | ||||
| Grand Gulf 1 | 100 | ||||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 100 | ||||
| River Bend 1 | 0 | 01/06/2008 | DEFUELED | ||
| San Onofre 2 | 98 | ADMINISTRATIVE LIMIT BASED ON STEAM GENERATOR LIMITATIONS | |||
| San Onofre 3 | 100 | ||||
| South Texas 1 | 100 | ||||
| South Texas 2 | 100 | ||||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 100 |
Page Last Reviewed/Updated Wednesday, March 24, 2021