Power Reactor Status Report for February 28, 2007

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 0 02/25/2007 REFUELING OUTAGE    
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100        
Limerick 2 98   COASTDOWN TO REFUELING OUTAGE *  
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 89   COASTDOWN TO REFUELING OUTAGE    
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 77   INCREASING POWER TO 100% - TEMPORARY POWER INSTALLED TO ISOPHASE BUS DUCT COOLING FAN - UE DECLARED DUE TO FIRE INSIDE THE TURBINE AREA LOAD CENTER - SEE EVENT #43189 *  
Pilgrim 1 90   COASTDOWN TO REFUELING OUTAGE *  
Salem 1 100        
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 100        
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/03/1985 CORE LOADED CAVITY FLOODED 500 KV (MADISON) LINE OOS    
Browns Ferry 2 0 02/20/2007 REFUELING OUTAGE 500 KV (MADISON) LINE OOS    
Browns Ferry 3 100   500 KV (MADISON) LINE OOS    
Brunswick 1 100        
Brunswick 2 100   COASTDOWN TO REFUELING OUTAGE    
Catawba 1 100        
Catawba 2 100        
Crystal River 3 99   HOLDING POWER FOR MAINTENANCE *  
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 0 02/05/2007 REFUELING OUTAGE    
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 31   HOLDING POWER - EXITED TS REQUIRED SHUTDOWN - SEE EVENT #43195 *  
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 98   100% ELECTRICAL CAPABILITY    
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 96   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 98   100% ELECTRICAL CAPABILITY *  
Dresden 3 99   100% ELECTRICAL CAPABILITY *  
Duane Arnold 0 02/04/2007 REFUELING OUTAGE. 1 OF 4 161 KV LINES OOS. *  
Fermi 2 100     *  
Kewaunee 0 02/27/2007 REACTOR TRIP. SEE EN #43196. * 1
La Salle 1 100        
La Salle 2 0 02/25/2007 REFUELING OUTAGE. 345 KV 0102 PLANO LINE DOWN FOR PLANNED MAINTENANCE.    
Monticello 100        
Palisades 0 02/26/2007 ENTERING PLANNED MAINTENANCE OUTAGE.    
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100   345 KV OFFSITE PWR LINE OOS UNTIL 1ST WEEK IN MAY    
Prairie Island 2 100   ENTERING MAINTENANCE OUTAGE LATER TODAY. 345 KV OFFSITE PWR LINE OOS UNTIL 1ST WEEK IN MAY *  
Quad Cities 1 97   100% ELECTRICAL CAPABILITY    
Quad Cities 2 0 02/27/2007 REACTOR SCRAM. FORMAL REPORT FOR SCRAM NOT YET RECEIVED. * 1

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 0 02/24/2007 REFUELING OUTAGE    
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 97   COASTDOWN TO REFUELING OUTAGE *  
Palo Verde 1 100        
Palo Verde 2 100     *  
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 100        
San Onofre 3 100        
South Texas 1 100        
South Texas 2 93   COASTDOWN TO REFUELING OUTAGE *  
Waterford 3 100        
Wolf Creek 1 100        