Power Reactor Status Report for December 13, 2006
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 100 | ||||
| Beaver Valley 2 | 100 | ||||
| Calvert Cliffs 1 | 0 | 12/12/2006 | RCS COOLDOWN IN PROGRESS - ENTERING MODE 4 FOR "12A" RCP CCW REPAIR - MANUAL RX TRIP DURING TURBINE CONTROL SYSTEM MAINTENANCE - SEE EVENT #43046 | * | 1 |
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 100 | ||||
| Ginna | 100 | ||||
| Hope Creek 1 | 100 | * | |||
| Indian Point 2 | 100 | ||||
| Indian Point 3 | 100 | ||||
| Limerick 1 | 100 | ||||
| Limerick 2 | 100 | ||||
| Millstone 2 | 100 | ||||
| Millstone 3 | 100 | ||||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 100 | ||||
| Oyster Creek | 100 | ||||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 100 | ||||
| Salem 1 | 100 | ||||
| Salem 2 | 100 | ||||
| Seabrook 1 | 100 | ||||
| Susquehanna 1 | 100 | GENERATOR VOLTAGE REGULATOR IN MANUAL | |||
| Susquehanna 2 | 100 | ||||
| Three Mile Island 1 | 100 | ||||
| Vermont Yankee | 100 |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 0 | 03/03/1985 | DEFUELED | ||
| Browns Ferry 2 | 100 | 1 OF 7 500 KV LINES OOS FOR PLANNED MAINTENANCE | |||
| Browns Ferry 3 | 100 | 1 OF 7 500 KV LINES OOS FOR PLANNED MAINTENANCE | * | ||
| Brunswick 1 | 95 | REDUCED POWER FOR CONTROL ROD TESTING AND PLANNED MAINTENANCE | * | ||
| Brunswick 2 | 100 | ||||
| Catawba 1 | 0 | 11/10/2006 | DEFUELED | ||
| Catawba 2 | 98 | CURRENTLY SUPPLYING AUX STEAM TO UNIT 1 | * | ||
| Crystal River 3 | 100 | ||||
| Farley 1 | 100 | ||||
| Farley 2 | 100 | ||||
| Harris 1 | 100 | ||||
| Hatch 1 | 100 | ||||
| Hatch 2 | 100 | ||||
| McGuire 1 | 100 | ||||
| McGuire 2 | 100 | ||||
| North Anna 1 | 100 | ||||
| North Anna 2 | 100 | ||||
| Oconee 1 | 0 | 10/06/2006 | RX SUBCRITICIAL - CURRENTLY PERFORMING LOW POWER PHYSICS TESTING | * | |
| Oconee 2 | 100 | ||||
| Oconee 3 | 100 | ||||
| Robinson 2 | 100 | ||||
| Saint Lucie 1 | 100 | ||||
| Saint Lucie 2 | 99 | DEH CONTROL SYSTEM MAINTENANCE | |||
| Sequoyah 1 | 100 | ||||
| Sequoyah 2 | 0 | 11/26/2006 | LOADING FUEL | ||
| Summer | 100 | ||||
| Surry 1 | 100 | ||||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 57 | INCREASING POWER | * | ||
| Vogtle 1 | 100 | ||||
| Vogtle 2 | 100 | ||||
| Watts Bar 1 | 95 | HOLDING FOR FUEL PRECONDITIONING - ANTICIPATE INCREASING TO 100% POWER LATER TODAY | * |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | ||||
| Byron 2 | 100 | ||||
| Clinton | 96 | 100% ELECTRICAL CAPABILITY | |||
| D.C. Cook 1 | 100 | ||||
| D.C. Cook 2 | 100 | ||||
| Davis-Besse | 100 | ||||
| Dresden 2 | 97 | 100% ELECTRICAL CAPABILITY | |||
| Dresden 3 | 98 | 100% ELECTRICAL CAPABILITY | * | ||
| Duane Arnold | 98 | 100% ELECTRICAL CAPABILITY | |||
| Fermi 2 | 100 | MAINTENANCE ON ONE OF THREE 120KV LINES | |||
| Kewaunee | 99 | * | |||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 100 | ||||
| Palisades | 100 | ||||
| Perry 1 | 100 | ||||
| Point Beach 1 | 100 | ||||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | ||||
| Prairie Island 2 | 0 | 11/14/2006 | COMING OUT OF REFUELING OUTAGE - HEATUP IN PROGRESS | ||
| Quad Cities 1 | 97 | 100% ELECTRICAL CAPABILITY | * | ||
| Quad Cities 2 | 95 | 100% ELECTRICAL CAPABILITY |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | ||||
| Comanche Peak 1 | 100 | ||||
| Comanche Peak 2 | 100 | ||||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 100 | ||||
| Diablo Canyon 2 | 0 | 12/10/2006 | UE DECLARED SEE EN# 43047 | * | 1 |
| Fort Calhoun | 100 | * | |||
| Grand Gulf 1 | 100 | ||||
| Palo Verde 1 | 100 | ||||
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 100 | ||||
| River Bend 1 | 100 | ||||
| San Onofre 2 | 99 | STEAM GENERATOR TUBE PLUGGING LIMITATION | |||
| San Onofre 3 | 0 | 12/12/2006 | FORCED OUTAGE TO REPAIR OIL LEAK ON REACTOR COOLANT PUMP | * | |
| South Texas 1 | 100 | ||||
| South Texas 2 | 100 | ||||
| Waterford 3 | 0 | 11/25/2006 | REFUELING OUTAGE | ||
| Wolf Creek 1 | 100 |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021