Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for April 10, 2005

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 0 04/03/2005 REFUELING OUTAGE    
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 0 03/20/2005 REFUELING    
Hope Creek 1 23   INCREASING POWER *  
Indian Point 2 100        
Indian Point 3 90   HOLDING POWER FOR NI CALIBRATION *  
Limerick 1 100        
Limerick 2 100        
Millstone 2 0 04/08/2005 ENTERING REFUELING OUTAGE *  
Millstone 3 100        
Nine Mile Point 1 0 03/20/2005 DEFUELED    
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 88   COASTDOWN TO REFUELING OUTAGE *  
Salem 1 83   REDUCED POWER DUE TO RIVER GRASS AT INTAKE TO CIRC WATER PUMPS *  
Salem 2 0 04/05/2005 REFUELING OUTAGE    
Seabrook 1 0 03/31/2005 DEFUELED *  
Susquehanna 1 100        
Susquehanna 2 100        
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/03/1985 DEFUELED    
Browns Ferry 2 0 03/21/2005 REFUELING OUTAGE *  
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 0 04/09/2005 AUTOMATIC REACTOR SCRAM DUE TO LOW REACTOR VESSEL WATER LEVEL. SEE EVENT # 41582. *  
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 66   HOLDING POWER FOR PLANNED MAINTENANCE *  
Hatch 2 100        
McGuire 1 100        
McGuire 2 0 03/01/2005 STARTUP PREPARATIONS IN PROGRESS    
North Anna 1 100        
North Anna 2 100        
Oconee 1 0 04/08/2005 ENTERING REFUELING OUTAGE *  
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 0 04/09/2005 AUTOMATIC REACTOR TRIP DUE TO TURBINE TRIP ON LOW AUTO STOP OIL PRESSURE SWITCHES. SEE EVENT # 41583. * 1
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 60   HOLDING FOR FEED PUMP MAINTENANCE    
Vogtle 1 30   HOLDING POWER FOR FLUX MAPPING *  
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 86   REDUCED POWER FOR TURBINE VALVE TEST *  
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 92   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 0 03/26/2005 DEFUELED    
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 98   100% ELECTRICAL CAPABILITY    
Dresden 3 98   100% ELECTRICAL CAPABILITY    
Duane Arnold 0 03/28/2005 REFUELING OUTAGE    
Fermi 2 100        
Kewaunee 0 02/20/2005 SHUTDOWN TO RESOLVE AUXILIARY FEEDWATER ISSUE    
La Salle 1 100        
La Salle 2 100        
Monticello 0 04/09/2005 HOLDING FOR TEST *  
Palisades 100        
Perry 1 0 02/21/2005 REFUELING OUTAGE    
Point Beach 1 100        
Point Beach 2 0 04/01/2005 REFUELING OUTAGE    
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 0 03/21/2005 REFUELING OUTAGE    
Quad Cities 2 85   LIMITED IN POWER (STEAM DRYER MONITORING)    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 0 03/08/2005 HEATING TO CRITICALITY *  
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 0 03/26/2005 DEFUELED    
Cooper 98   HOLDING POWER *  
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 0 02/26/2005 DEFUELED    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 0 04/01/2005 REFUELING OUTAGE    
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 100        
San Onofre 3 100        
South Texas 1 0 03/08/2005 REFUELING OUTAGE    
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 0 04/08/2005 REFUELING OUTAGE *  

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021