Power Reactor Status Report for April 7, 2004
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Beaver Valley 1 | 100 | ||||
| Beaver Valley 2 | 100 | ||||
| Calvert Cliffs 1 | 100 | ||||
| Calvert Cliffs 2 | 100 | ||||
| FitzPatrick | 100 | ||||
| Ginna | 100 | ||||
| Hope Creek 1 | 0 | 03/20/2004 | MAINTENANCE OUTAGE. PREPARING FOR STARTUP | * | |
| Indian Point 2 | 100 | ||||
| Indian Point 3 | 100 | ||||
| Limerick 1 | 100 | ||||
| Limerick 2 | 100 | ||||
| Millstone 2 | 100 | ||||
| Millstone 3 | 0 | 04/02/2004 | REFUELING OUTAGE | ||
| Nine Mile Point 1 | 100 | ||||
| Nine Mile Point 2 | 0 | 03/15/2004 | REFUELING OUTAGE | ||
| Oyster Creek | 100 | ||||
| Peach Bottom 2 | 100 | ||||
| Peach Bottom 3 | 100 | ||||
| Pilgrim 1 | 100 | ||||
| Salem 1 | 0 | 03/30/2004 | REFUELING OUTAGE | ||
| Salem 2 | 98 | HEATER DRAIN PUMP ISSUE | |||
| Seabrook 1 | 100 | ||||
| Susquehanna 1 | 0 | 02/27/2004 | REFUELING OUTAGE | ||
| Susquehanna 2 | 100 | ||||
| Three Mile Island 1 | 100 | ||||
| Vermont Yankee | 0 | 04/03/2004 | REFUELING OUTAGE |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Browns Ferry 1 | 0 | 02/16/2004 | DEFUELED | ||
| Browns Ferry 2 | 100 | ||||
| Browns Ferry 3 | 100 | ||||
| Brunswick 1 | 60 | POWER ASCENSION TESTING | * | ||
| Brunswick 2 | 96 | 100% ELECTRICAL CAPABILITY | |||
| Catawba 1 | 100 | ||||
| Catawba 2 | 100 | ||||
| Crystal River 3 | 100 | ||||
| Farley 1 | 100 | ||||
| Farley 2 | 0 | 03/12/2004 | STARTUP PREPARATIONS IN PROGRESS | ||
| Harris 1 | 100 | ||||
| Hatch 1 | 99 | MAXIMUM OPERATING POWER (MOP) | |||
| Hatch 2 | 99 | MAXIMUM OPERATING POWER (MOP) | * | ||
| McGuire 1 | 0 | 03/06/2004 | MAINTENANCE ON MSIV | * | |
| McGuire 2 | 100 | ||||
| North Anna 1 | 100 | ||||
| North Anna 2 | 100 | ||||
| Oconee 1 | 100 | ||||
| Oconee 2 | 0 | 03/19/2004 | REFUELING OUTAGE DEFUELED | ||
| Oconee 3 | 100 | ||||
| Robinson 2 | 100 | ||||
| Saint Lucie 1 | 0 | 03/21/2004 | DEFUELED | ||
| Saint Lucie 2 | 100 | ||||
| Sequoyah 1 | 100 | ||||
| Sequoyah 2 | 100 | ||||
| Summer | 0 | 03/30/2004 | SHUTDOWN FOR REACTOR COOLANT PUMP SEAL INJECTION LINE MAINTENANCE | ||
| Surry 1 | 100 | ||||
| Surry 2 | 100 | ||||
| Turkey Point 3 | 100 | ||||
| Turkey Point 4 | 100 | ||||
| Vogtle 1 | 100 | ||||
| Vogtle 2 | 100 | ||||
| Watts Bar 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Braidwood 1 | 100 | ||||
| Braidwood 2 | 100 | ||||
| Byron 1 | 100 | ||||
| Byron 2 | 0 | 03/22/2004 | REFUELING OUTAGE | ||
| Clinton | 93 | 100% ELECTRICAL CAPABILITY | * | ||
| D.C. Cook 1 | 7 | INCREASING POWER | * | ||
| D.C. Cook 2 | 82 | TURBINE CONTROL PROBLEM | * | ||
| Davis-Besse | 100 | * | |||
| Dresden 2 | 97 | 100% ELECTRICAL CAPABILITY | * | ||
| Dresden 3 | 99 | 100% ELECTRICAL CAPABILITY | |||
| Duane Arnold | 94 | 100% ELECTRICAL CAPABILITY. NOTE THAT PLANT REPORTS 100% DESIGN CAPABILITY VICE 94% THERMAL POWER/100% ELECTRIC CAPABILITY. | |||
| Fermi 2 | 100 | ||||
| Kewaunee | 100 | ||||
| La Salle 1 | 100 | ||||
| La Salle 2 | 100 | ||||
| Monticello | 100 | ||||
| Palisades | 100 | ||||
| Perry 1 | 100 | ||||
| Point Beach 1 | 0 | 04/02/2004 | REFUELING OUTAGE | ||
| Point Beach 2 | 100 | ||||
| Prairie Island 1 | 100 | ||||
| Prairie Island 2 | 100 | ||||
| Quad Cities 1 | 85 | LIMITED IN POWER (STEAM DRYER MONITORING) | |||
| Quad Cities 2 | 85 | LIMITED IN POWER (STEAM DRYER MONITORING) |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
|---|---|---|---|---|---|
| Arkansas Nuclear 1 | 100 | ||||
| Arkansas Nuclear 2 | 100 | ||||
| Callaway | 100 | ||||
| Columbia Generating Station | 100 | ||||
| Comanche Peak 1 | 0 | 03/27/2004 | DEFUELED | ||
| Comanche Peak 2 | 100 | * | |||
| Cooper | 100 | ||||
| Diablo Canyon 1 | 0 | 03/22/2004 | DEFUELED | ||
| Diablo Canyon 2 | 100 | ||||
| Fort Calhoun | 7 | INCREASING POWER | * | ||
| Grand Gulf 1 | 100 | ||||
| Palo Verde 1 | 0 | 04/02/2004 | REFUELING OUTAGE | * | |
| Palo Verde 2 | 100 | ||||
| Palo Verde 3 | 99 | T-HOT LIMITED | |||
| River Bend 1 | 100 | ||||
| San Onofre 2 | 29 | INCREASING POWER | * | ||
| San Onofre 3 | 100 | ||||
| South Texas 1 | 100 | ||||
| South Texas 2 | 0 | 03/31/2004 | REFUELING OUTAGE | ||
| Waterford 3 | 100 | ||||
| Wolf Creek 1 | 100 |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021