Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for December 31, 2003

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 82   DOWNPOWER TO CLEAN CONDENSER WATERBOX    
Salem 2 99   LIMITED BY TURBINE CONTROLS    
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 100        
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/03/1985 DEFUELED    
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 93   100% ELECTRICAL CAPABILITY *  
Brunswick 2 91   REDUCED POWER FOR TURBINE EHC LEAK REPAIRS *  
Catawba 1 10   TURBINE MAINTENANCE    
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 96   FUEL LEAKER - COASTDOWN    
Hatch 2 99   LIMITED BY TURBINE CONTROLS    
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 0 12/17/2003 MAINTENANCE OUTAGE    
Oconee 2 100        
Oconee 3 100        
Robinson 2 98   REDUCED POWER FOR LOOP 2 OVER-POWER DELTA TEMPERATURE *  
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 0 12/27/2003 SHUTDOWN FOR GENERATOR HYDROGEN LEAK    
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 93   DECREASING TO 20% POWER FOR FEEDWATER VALVE MAINTENANCE *  
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 84   COASTDOWN TO REFUELING OUTAGE    
D.C. Cook 1 100        
D.C. Cook 2 0 12/30/2003 REACTOR TRIP - SEE EN# 40419 *  
Davis-Besse 0 02/15/2002 MAINTENANCE OUTAGE *  
Dresden 2 97   100% ELECTRICAL CAPABILITY *  
Dresden 3 97   100% ELECTRICAL CAPABILITY    
Duane Arnold 94   100% ELECTRICAL CAPABILITY    
Fermi 2 100        
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 98   HEATER DRAIN PUMP SEAL ADJUSTMENT *  
Quad Cities 1 85   LIMITED IN POWER (STEAM DRYER MONITORING).    
Quad Cities 2 95   100% ELECTRICAL CAPABILITY    

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 91   INCREASING POWER *  
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 99        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 99   T-HOT LIMITED *  
Palo Verde 2 100        
Palo Verde 3 99   T-HOT LIMITED    
River Bend 1 100        
San Onofre 2 100        
San Onofre 3 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

Page Last Reviewed/Updated Wednesday, March 24, 2021