Skip to main content

Power Reactor Status Report for February 27, 2003

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 25   Power Operation
INCREASING POWER
*  
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 0 02/14/2003 Refueling
REFUELING OUTAGE
   
FITZPATRICK 1 100        
GINNA 1 100        
HOPE CREEK 1 99     *  
INDIAN POINT 2 100        
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 96   Power Operation
COASTDOWN TO REFUELING OUTAGE
*  
MILLSTONE 2 100        
MILLSTONE 3 100        
NINE MILE POINT 1 100        
NINE MILE POINT 2 100        
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100        
PILGRIM 1 0 02/21/2003 Refueling
PREPARING FOR RESTART
   
SALEM 1 100        
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 87   Power Operation
COASTDOWN TO REFUELING OUTAGE
   
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 Refueling
DEFUELED
   
BROWNS FERRY 2 0 02/24/2003 Refueling
SHUTDOWN FOR REFUELING OUTAGE
   
BROWNS FERRY 3 100        
BRUNSWICK 1 94   Power Operation
100% ELECTRICAL POWER
   
BRUNSWICK 2 97   Power Operation
COAST DOWN TO REFUELING OUTAGE
*  
CATAWBA 1 100        
CATAWBA 2 95     *  
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 100        
HARRIS 1 100        
HATCH 1 100        
HATCH 2 100        
MCGUIRE 1 100        
MCGUIRE 2 100        
NORTH ANNA 1 0 02/22/2003 Refueling
PREPARATIONS IN PROGRESS FOR REFUELING OUTAGE
*  
NORTH ANNA 2 100        
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 100        
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 100        
TURKEY POINT 3 60   Power Operation
HOLDING POWER FOR REPAIRS TO STEAM GENERATOR FEED PUMP
   
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 100        
BYRON 1 99        
BYRON 2 100        
CLINTON 1 91   Power Operation
100% ELECTRICAL CAPABILITY
   
COOK 1 100        
COOK 2 100        
DAVIS BESSE 1 0 02/15/2002 Refueling
REFUELING OUTAGE
   
DRESDEN 2 78   Power Operation
FEED PUMP MAINTENANCE
*  
DRESDEN 3 97   Power Operation
100% ELECTRICAL CAPABILITY
   
DUANE ARNOLD 1 93   Power Operation
100% ELECTRICAL CAPABILITY
   
FERMI 2 100        
KEWAUNEE 1 45   Power Operation
HOLDING POWER. SEE EN#39620.
*  
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 100        
PALISADES 1 100        
PERRY 1 85   Power Operation
COASTDOWN TO REFUELING OUTAGE
*  
POINT BEACH 1 100        
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 97   Power Operation
100% ELECTRICAL CAPABILITY
   
QUAD CITIES 2 98   Power Operation
100% ELECTRICAL CAPABILITY
*  

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 100        
COLUMBIA GENERATING 100        
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 100        
COOPER 1 0 02/23/2003 Cold Shutdown
SHUTTING DOWN FOR OUTAGE
   
DIABLO CANYON 1 100        
DIABLO CANYON 2 0 02/03/2003 Refueling
REFUELING OUTAGE
   
FT CALHOUN 1 100        
GRAND GULF 1 100        
PALO VERDE 1 97   Power Operation
RCS T hot Temperature Limited
   
PALO VERDE 2 98   Power Operation
RCS T hot Temperature Limited
   
PALO VERDE 3 99   Power Operation
RCS T hot Temperature Limited
   
RIVER BEND 1 90   Power Operation
COASTDOWN TO REFUELING OUTAGE
*  
SAN ONOFRE 2 100        
SAN ONOFRE 3 98   Power Operation
HOLDING POWER FOR COMPLETION OF ENGINEERING EVALUATION
   
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 0 01/24/2003 Cold Shutdown
MAINTENANCE OUTAGE
   
WATERFORD 3 100   Power Operation
POWER REDUCED FOR MAINTENANCE
*  
WOLF CREEK 1 100        

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021