Power Reactor Status Report for April 14, 2002
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
---|---|---|---|---|---|
BEAVER VALLEY 1 | 90 | Cleaning condenser water boxes. | |||
BEAVER VALLEY 2 | 100 | ||||
CALVERT CLIFFS 1 | 0 | 02/15/2002 | REFUELING OUTAGE - DEFUELED | ||
CALVERT CLIFFS 2 | 100 | ||||
FITZPATRICK 1 | 100 | ||||
GINNA 1 | 0 | 03/18/2002 | REFUELING OUTAGE - REFUELING COMPLETE | ||
HOPE CREEK 1 | 98 | * | |||
INDIAN POINT 2 | 100 | ||||
INDIAN POINT 3 | 100 | ||||
LIMERICK 1 | 100 | ||||
LIMERICK 2 | 100 | ||||
MILLSTONE 2 | 23 | INCREASING POWER | * | ||
MILLSTONE 3 | 100 | ||||
NINE MILE POINT 1 | 100 | ||||
NINE MILE POINT 2 | 0 | 03/15/2002 | REFUELING OUTAGE - REFUELED | * | |
OYSTER CREEK 1 | 40 | MAINTENANCE WORK | * | ||
PEACH BOTTOM 2 | 100 | ||||
PEACH BOTTOM 3 | 100 | ||||
PILGRIM 1 | 100 | ||||
SALEM 1 | 100 | ||||
SALEM 2 | 0 | 04/04/2002 | REFUELING OUTAGE | ||
SEABROOK 1 | 100 | ||||
SUSQUEHANNA 1 | 0 | 03/02/2002 | REFUELING OUTAGE | ||
SUSQUEHANNA 2 | 100 | ||||
THREE MILE ISLAND 1 | 100 | ||||
VERMONT YANKEE 1 | 91 | HOLDING POWER DUE TO FUEL PROBLEMS |
Region 2
Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
---|---|---|---|---|---|
BROWNS FERRY 1 | 0 | 03/03/1985 | DEFUELED | ||
BROWNS FERRY 2 | 100 | ||||
BROWNS FERRY 3 | 100 | * | |||
BRUNSWICK 1 | 62 | Power suppression testing in progress to locate and SUPPRESS reactor fuel leak. | * | ||
BRUNSWICK 2 | 100 | ||||
CATAWBA 1 | 98 | COASTDOWN TO REFUELING OUTAGE | |||
CATAWBA 2 | 100 | ||||
CRYSTAL RIVER 3 | 100 | ||||
FARLEY 1 | 100 | ||||
FARLEY 2 | 100 | ||||
HARRIS 1 | 100 | ||||
HATCH 1 | 0 | 03/23/2002 | REFUELING OUTAGE | ||
HATCH 2 | 100 | ||||
MCGUIRE 1 | 100 | ||||
MCGUIRE 2 | 100 | ||||
NORTH ANNA 1 | 100 | ||||
NORTH ANNA 2 | 100 | ||||
OCONEE 1 | 0 | 03/23/2002 | REFUELING OUTAGE | ||
OCONEE 2 | 100 | ||||
OCONEE 3 | 100 | ||||
ROBINSON 2 | 100 | ||||
SAINT LUCIE 1 | 100 | ||||
SAINT LUCIE 2 | 100 | ||||
SEQUOYAH 1 | 100 | ||||
SEQUOYAH 2 | 89 | COASTDOWN TO REFUELING OUTAGE | * | ||
SUMMER 1 | 100 | ||||
SURRY 1 | 100 | ||||
SURRY 2 | 0 | 03/24/2002 | |||
TURKEY POINT 3 | 100 | ||||
TURKEY POINT 4 | 100 | Repaired controllers for heater drain pumps. | |||
VOGTLE 1 | 0 | 03/06/2002 | REFUELING OUTAGE | ||
VOGTLE 2 | 100 | ||||
WATTS BAR 1 | 100 |
Region 3
Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
---|---|---|---|---|---|
BRAIDWOOD 1 | 100 | ||||
BRAIDWOOD 2 | 95 | 100% ELECTRICAL CAPABILITY | |||
BYRON 1 | 100 | ||||
BYRON 2 | 100 | MEASURED STEAM GENERATOR TUBE LEAKAGE LESS THAN 5 GPD | |||
CLINTON 1 | 0 | 04/01/2002 | REFUELING OUTAGE | ||
COOK 1 | 100 | ||||
COOK 2 | 100 | ||||
DAVIS BESSE 1 | 0 | 02/15/2002 | REFUELING OUTAGE | ||
DRESDEN 2 | 96 | 100% ELECTRICAL CAPABILITY | |||
DRESDEN 3 | 100 | ||||
DUANE ARNOLD 1 | 94 | 100% ELECTRICAL CAPABILITY | |||
FERMI 2 | 100 | ||||
KEWAUNEE 1 | 100 | ||||
LASALLE 1 | 100 | ||||
LASALLE 2 | 0 | 04/08/2002 | PLANNED MAINTENANCE OUTAGE | ||
MONTICELLO 1 | 100 | ||||
PALISADES 1 | 99 | * | |||
PERRY 1 | 93 | REDUCED POWER FOR TURBINE TEST | * | ||
POINT BEACH 1 | 100 | ||||
POINT BEACH 2 | 0 | 04/12/2002 | Shutdown for refueling outage. | * | |
PRAIRIE ISLAND 1 | 100 | ||||
PRAIRIE ISLAND 2 | 100 | ||||
QUAD CITIES 1 | 100 | * | |||
QUAD CITIES 2 | 70 | REDUCED POWER FOR CONTROL ROD PATTERN ADJUSTMENT | * |
Region 4
Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
---|---|---|---|---|---|
ARKANSAS NUCLEAR 1 | 100 | ||||
ARKANSAS NUCLEAR 2 | 0 | 04/12/2002 | REFUELING OUTAGE | * | |
CALLAWAY 1 | 100 | ||||
COLUMBIA GENERATING | 100 | ||||
COMANCHE PEAK 1 | 100 | ||||
COMANCHE PEAK 2 | 0 | 03/30/2002 | REFUELING OUTAGE - DEFUELED | ||
COOPER 1 | 100 | ||||
DIABLO CANYON 1 | 100 | ||||
DIABLO CANYON 2 | 100 | ||||
FT CALHOUN 1 | 98 | ||||
GRAND GULF 1 | 100 | ||||
PALO VERDE 1 | 99 | ||||
PALO VERDE 2 | 0 | 03/15/2002 | REFUELING OUTAGE - REFUELED | * | |
PALO VERDE 3 | 99 | ||||
RIVER BEND 1 | 100 | ||||
SAN ONOFRE 2 | 100 | ||||
SAN ONOFRE 3 | 100 | ||||
SOUTH TEXAS 1 | 100 | ||||
SOUTH TEXAS 2 | 100 | ||||
WATERFORD 3 | 0 | 03/22/2002 | REFUELING OUTAGE - REFUELED | * | |
WOLF CREEK 1 | 0 | 03/23/2002 | REFUELING OUTAGE |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021