Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for October 30, 2001

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 100        
BEAVER VALLEY 2 100        
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 100        
FITZPATRICK 1 85   INCREASING POWER AFTER DECREASING TO 65% DUE TO A RECIRCULATION PUMP TRIP *  
GINNA 1 100        
HOPE CREEK 1 0 10/09/2001 REFUELING OUTAGE    
INDIAN POINT 2 0 10/26/2001 MAINTENANCE OUTAGE    
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 100        
MILLSTONE 2 100        
MILLSTONE 3 100        
NINE MILE POINT 1 100        
NINE MILE POINT 2 100        
OYSTER CREEK 1 100        
PEACH BOTTOM 2 73   INCREASING POWER AFTER EXITING A MAINTENANCE OUTAGE *  
PEACH BOTTOM 3 100        
PILGRIM 1 100        
SALEM 1 100        
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 100        
THREE MILE ISLAND 1 0 10/08/2001 REFUELING OUTAGE - DEFUELED    
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 100        
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 0 10/05/2001 REFUELING OUTAGE    
FARLEY 2 100        
HARRIS 1 0 09/21/2001 REFUELING OUTAGE - DEFUELED    
HATCH 1 100        
HATCH 2 47   INCREASING POWER AFTER EXITING A MAINTENANCE OUTAGE *  
MCGUIRE 1 100        
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 0 10/28/2001 MAINTENANCE OUTAGE *  
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 100        
ROBINSON 2 100        
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 0 10/21/2001 REFUELING OUTAGE - DEFUELED    
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 0 10/14/2001 REFUELING OUTAGE - DEFUELED    
SURRY 2 100        
TURKEY POINT 3 71   SLOWLY INCREASING POWER AFTER EXITING A REFUELING OUTAGE *  
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100        
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 83   HOLDING POWER AT THIS LEVEL DUE TO TURBINE GENERATOR VIBRATION    
BYRON 1 99   100% OF RATED ELECTRICAL CAPABILITY    
BYRON 2 100        
CLINTON 1 100        
COOK 1 94   INCREASING POWER AFTER DECREASING TO 80% TO EVALUATE A CIRCULATING WATER PUMP PROBLEM *  
COOK 2 100     *  
DAVIS BESSE 1 100        
DRESDEN 2 0 10/20/2001 REFUELING OUTAGE - FUEL SHUFFLE IN PROGRESS *  
DRESDEN 3 100        
DUANE ARNOLD 1 100        
FERMI 2 0 10/27/2001 REFUELING OUTAGE - PREPARING FOR FUEL OFFLOAD *  
KEWAUNEE 1 0 09/23/2001 REFUELING OUTAGE - DEFUELED    
LASALLE 1 100        
LASALLE 2 100        
MONTICELLO 1 95   COASTDOWN TO REFUELING OUTAGE    
PALISADES 1 0 06/20/2001 MAINTENANCE OUTAGE    
PERRY 1 100        
POINT BEACH 1 100        
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 100        

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 100        
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 100        
COLUMBIA GENERATING 100        
COMANCHE PEAK 1 100        
COMANCHE PEAK 2 100        
COOPER 1 95   COASTDOWN TO REFUELING OUTAGE    
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 100        
GRAND GULF 1 100        
PALO VERDE 1 99        
PALO VERDE 2 0 10/10/2001 MAINTENANCE OUTAGE    
PALO VERDE 3 0 09/28/2001 REFUELING OUTAGE *  
RIVER BEND 1 2   MAINTENANCE OUTAGE - STARTUP IN PROGRESS *  
SAN ONOFRE 2 100        
SAN ONOFRE 3 100        
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 100        
WATERFORD 3 100        
WOLF CREEK 1 100        