Power Reactor Status Report for June 23, 2001
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) | 
|---|---|---|---|---|---|
| BEAVER VALLEY 1 | 0 | 06/22/2001 | MANUAL REACTOR TRIP DUE TO LOSS OF RCP COOLING WATER SUPPLY. SEE EVENT # 38086. | * | 1 | 
| BEAVER VALLEY 2 | 100 | ||||
| CALVERT CLIFFS 1 | 100 | ||||
| CALVERT CLIFFS 2 | 100 | ||||
| FITZPATRICK 1 | 100 | ||||
| GINNA 1 | 100 | ||||
| HOPE CREEK 1 | 100 | ||||
| INDIAN POINT 2 | 100 | ||||
| INDIAN POINT 3 | 100 | ||||
| LIMERICK 1 | 100 | ||||
| LIMERICK 2 | 100 | ||||
| MILLSTONE 2 | 100 | ||||
| MILLSTONE 3 | 100 | ||||
| NINE MILE POINT 1 | 100 | ||||
| NINE MILE POINT 2 | 93 | POWER LIMITED DUE TO ONE RECIRCULATION FLOW CONTROL VALVE HYDRAULICALLY LOCKING UP. | * | ||
| OYSTER CREEK 1 | 100 | ||||
| PEACH BOTTOM 2 | 100 | ||||
| PEACH BOTTOM 3 | 97 | COASTDOWN TO REFUELING OUTAGE | |||
| PILGRIM 1 | 30 | INVESTIGATING DEGRADED CONDENSER VACUUM. | * | ||
| SALEM 1 | 100 | ||||
| SALEM 2 | 100 | ||||
| SEABROOK 1 | 100 | ||||
| SUSQUEHANNA 1 | 100 | ||||
| SUSQUEHANNA 2 | 100 | ||||
| THREE MILE ISLAND 1 | 100 | ||||
| VERMONT YANKEE 1 | 100 | 
Region 2
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) | 
|---|---|---|---|---|---|
| BROWNS FERRY 1 | 0 | 03/03/1985 | DEFUELED | ||
| BROWNS FERRY 2 | 100 | ||||
| BROWNS FERRY 3 | 100 | ||||
| BRUNSWICK 1 | 100 | ||||
| BRUNSWICK 2 | 60 | REDUCED POWER FOR ROD SHUFFLING. | * | ||
| CATAWBA 1 | 100 | ||||
| CATAWBA 2 | 100 | ||||
| CRYSTAL RIVER 3 | 100 | ||||
| FARLEY 1 | 100 | ||||
| FARLEY 2 | 100 | ||||
| HARRIS 1 | 100 | ||||
| HATCH 1 | 100 | ||||
| HATCH 2 | 100 | ||||
| MCGUIRE 1 | 100 | ||||
| MCGUIRE 2 | 100 | ||||
| NORTH ANNA 1 | 100 | ||||
| NORTH ANNA 2 | 100 | ||||
| OCONEE 1 | 100 | ||||
| OCONEE 2 | 100 | ||||
| OCONEE 3 | 100 | ||||
| ROBINSON 2 | 100 | ||||
| SAINT LUCIE 1 | 100 | ||||
| SAINT LUCIE 2 | 100 | ||||
| SEQUOYAH 1 | 100 | ||||
| SEQUOYAH 2 | 100 | ||||
| SUMMER 1 | 15 | MAIN TURBINE OFF LINE REPAIRING INTERMEDIATE VALVES. | * | ||
| SURRY 1 | 100 | ||||
| SURRY 2 | 100 | ||||
| TURKEY POINT 3 | 100 | ||||
| TURKEY POINT 4 | 100 | ||||
| VOGTLE 1 | 100 | ||||
| VOGTLE 2 | 100 | ||||
| WATTS BAR 1 | 100 | 
Region 3
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) | 
|---|---|---|---|---|---|
| BRAIDWOOD 1 | 97 | 100% OF RATED ELECTRICAL CAPABILITY | |||
| BRAIDWOOD 2 | 97 | 100% OF RATED ELECTRICAL CAPABILITY | |||
| BYRON 1 | 98 | 100% OF RATED ELECTRICAL CAPABILITY | * | ||
| BYRON 2 | 99 | * | |||
| CLINTON 1 | 100 | ||||
| COOK 1 | 100 | ||||
| COOK 2 | 100 | ||||
| DAVIS BESSE 1 | 90 | PLANNED MAINTENANCE ON FEEDWATER HEATERS | * | ||
| DRESDEN 2 | 100 | ||||
| DRESDEN 3 | 100 | ||||
| DUANE ARNOLD 1 | 100 | ||||
| FERMI 2 | 100 | ||||
| KEWAUNEE 1 | 96 | * | |||
| LASALLE 1 | 100 | ||||
| LASALLE 2 | 100 | ||||
| MONTICELLO 1 | 100 | ||||
| PALISADES 1 | 0 | 06/20/2001 | MAINTENANCE OUTAGE | * | |
| PERRY 1 | 70 | REDUCED REACTOR POWER FOR ROD SEQUENCE EXCHANGE. | * | ||
| POINT BEACH 1 | 100 | ||||
| POINT BEACH 2 | 100 | ||||
| PRAIRIE ISLAND 1 | 100 | ||||
| PRAIRIE ISLAND 2 | 100 | ||||
| QUAD CITIES 1 | 100 | ||||
| QUAD CITIES 2 | 100 | 
Region 4
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) | 
|---|---|---|---|---|---|
| ARKANSAS NUCLEAR 1 | 100 | ||||
| ARKANSAS NUCLEAR 2 | 100 | ||||
| CALLAWAY 1 | 100 | ||||
| COLUMBIA GENERATING | 0 | 05/19/2001 | REFUELING OUTAGE | ||
| COMANCHE PEAK 1 | 100 | ||||
| COMANCHE PEAK 2 | 100 | ||||
| COOPER 1 | 100 | ||||
| DIABLO CANYON 1 | 50 | HOLDING POWER LEVEL DUE TO CONTAMINATED CONDENSATE STORAGE TANK. | * | ||
| DIABLO CANYON 2 | 100 | ||||
| FT CALHOUN 1 | 100 | * | |||
| GRAND GULF 1 | 100 | ||||
| PALO VERDE 1 | 100 | ||||
| PALO VERDE 2 | 99 | ||||
| PALO VERDE 3 | 99 | ||||
| RIVER BEND 1 | 100 | ||||
| SAN ONOFRE 2 | 100 | ||||
| SAN ONOFRE 3 | 100 | ||||
| SOUTH TEXAS 1 | 100 | ||||
| SOUTH TEXAS 2 | 94 | REDUCED POWER FOR PLANNED MAINTENANCE | * | ||
| WATERFORD 3 | 100 | ||||
| WOLF CREEK 1 | 100 | 
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021
 
        