Power Reactor Status Report for May 9, 2001
UNEVALUATED INFORMATION PROVIDED BY THE FACILITY
On this page:
Region 1
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BEAVER VALLEY 1 | 100 | ||||
| BEAVER VALLEY 2 | 100 | ||||
| CALVERT CLIFFS 1 | 100 | ||||
| CALVERT CLIFFS 2 | 0 | 03/16/2001 | REFUELING OUTAGE | ||
| FITZPATRICK 1 | 100 | ||||
| GINNA 1 | 100 | ||||
| HOPE CREEK 1 | 0 | 05/08/2001 | TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO INOPERABILITY OF BOTH MAIN STEAM ISOLATION VALVE SEALING SYSTEM TRAINS (Refer to event #37972) | * | |
| INDIAN POINT 2 | 100 | * | |||
| INDIAN POINT 3 | 0 | 04/27/2001 | REFUELING OUTAGE - DEFUELED | * | |
| LIMERICK 1 | 100 | ||||
| LIMERICK 2 | 100 | ||||
| MILLSTONE 2 | 0 | 05/07/2001 | RECOVERING FROM A REACTOR TRIP ON LOSS OF A CIRCULATING WATER PUMP (Refer to event #37969) - UNIT CRITICAL | * | |
| MILLSTONE 3 | 100 | ||||
| NINE MILE POINT 1 | 24 | HOLDING POWER AT THIS LEVEL TO PERFORM TURBINE AND FEEDWATER SYSTEM TESTING AFTER EXITING A REFUELING OUTAGE | * | ||
| NINE MILE POINT 2 | 0 | 05/05/2001 | MAINTENANCE OUTAGE | * | |
| OYSTER CREEK 1 | 100 | ||||
| PEACH BOTTOM 2 | 100 | ||||
| PEACH BOTTOM 3 | 100 | ||||
| PILGRIM 1 | 0 | 04/21/2001 | REFUELING OUTAGE | ||
| SALEM 1 | 0 | 04/06/2001 | REFUELING OUTAGE | ||
| SALEM 2 | 100 | ||||
| SEABROOK 1 | 94 | HOLDING POWER AT THIS LEVEL DUE TO LOSS OF A CIRCULATING WATER PUMP | * | ||
| SUSQUEHANNA 1 | 75 | HOLDING POWER AT THIS LEVEL TO PERFORM REACTOR FEEDWATER PUMP REPAIRS | * | ||
| SUSQUEHANNA 2 | 100 | ||||
| THREE MILE ISLAND 1 | 53 | HOLDING POWER AT THIS LEVEL DUE TO A TRANSFORMER PROBLEM | * | ||
| VERMONT YANKEE 1 | 0 | 04/27/2001 | REFUELING OUTAGE - FIRST FUEL SHUFFLE COMPLETE | * |
Region 2
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BROWNS FERRY 1 | 0 | 03/03/1985 | DEFUELED | ||
| BROWNS FERRY 2 | 100 | ||||
| BROWNS FERRY 3 | 100 | ||||
| BRUNSWICK 1 | 100 | ||||
| BRUNSWICK 2 | 100 | ||||
| CATAWBA 1 | 100 | ||||
| CATAWBA 2 | 100 | ||||
| CRYSTAL RIVER 3 | 100 | ||||
| FARLEY 1 | 100 | ||||
| FARLEY 2 | 12 | REFUELING OUTAGE - PREPARING TO PLACE UNIT ON LINE | * | ||
| HARRIS 1 | 100 | ||||
| HATCH 1 | 100 | ||||
| HATCH 2 | 100 | ||||
| MCGUIRE 1 | 100 | ||||
| MCGUIRE 2 | 100 | ||||
| NORTH ANNA 1 | 100 | ||||
| NORTH ANNA 2 | 100 | ||||
| OCONEE 1 | 100 | ||||
| OCONEE 2 | 0 | 04/25/2001 | REFUELING OUTAGE - DEFUELED | * | |
| OCONEE 3 | 100 | ||||
| ROBINSON 2 | 0 | 04/06/2001 | REFUELING OUTAGE - HEATUP IN PROGRESS | * | |
| SAINT LUCIE 1 | 100 | ||||
| SAINT LUCIE 2 | 100 | ||||
| SEQUOYAH 1 | 100 | ||||
| SEQUOYAH 2 | 100 | ||||
| SUMMER 1 | 100 | ||||
| SURRY 1 | 100 | ||||
| SURRY 2 | 100 | ||||
| TURKEY POINT 3 | 100 | ||||
| TURKEY POINT 4 | 100 | ||||
| VOGTLE 1 | 100 | * | |||
| VOGTLE 2 | 100 | * | |||
| WATTS BAR 1 | 100 |
Region 3
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| BRAIDWOOD 1 | 100 | ||||
| BRAIDWOOD 2 | 100 | ||||
| BYRON 1 | 100 | ||||
| BYRON 2 | 100 | ||||
| CLINTON 1 | 100 | ||||
| COOK 1 | 100 | ||||
| COOK 2 | 100 | ||||
| DAVIS BESSE 1 | 100 | ||||
| DRESDEN 2 | 100 | ||||
| DRESDEN 3 | 100 | ||||
| DUANE ARNOLD 1 | 0 | 04/12/2001 | REFUELING OUTAGE - FUEL SHUFFLE COMPLETE | * | |
| FERMI 2 | 100 | ||||
| KEWAUNEE 1 | 96 | MAXIMUM POWER LEVEL DUE TO PLUGGED STEAM GENERATOR TUBES | |||
| LASALLE 1 | 100 | ||||
| LASALLE 2 | 100 | ||||
| MONTICELLO 1 | 47 | INCREASING POWER AFTER DECREASING TO 45% TO RESOLVE CONDENSATE DEMINERALIZER PROBLEMS | * | ||
| PALISADES 1 | 2 | REFUELING OUTAGE - LOW POWER PHYSICS TESTING COMPLETE | * | ||
| PERRY 1 | 0 | 05/08/2001 | MANUAL REACTOR SCRAM FROM 22% POWER DUE TO A RECIRCULATION PUMP PROBLEM (Refer to event #37971) | * | 1 |
| POINT BEACH 1 | 0 | 04/06/2001 | REFUELING OUTAGE | ||
| POINT BEACH 2 | 100 | ||||
| PRAIRIE ISLAND 1 | 100 | ||||
| PRAIRIE ISLAND 2 | 100 | ||||
| QUAD CITIES 1 | 100 | ||||
| QUAD CITIES 2 | 100 |
Region 4
| Unit | Power | Down | Reason or Comment | Change in report(*) | Number of Scrams(#) |
|---|---|---|---|---|---|
| ARKANSAS NUCLEAR 1 | 100 | ||||
| ARKANSAS NUCLEAR 2 | 100 | ||||
| CALLAWAY 1 | 0 | 04/06/2001 | REFUELING OUTAGE | ||
| COLUMBIA GENERATING | 85 | COASTDOWN TO REFUELING OUTAGE | * | ||
| COMANCHE PEAK 1 | 100 | ||||
| COMANCHE PEAK 2 | 100 | ||||
| COOPER 1 | 100 | ||||
| DIABLO CANYON 1 | 100 | ||||
| DIABLO CANYON 2 | 0 | 04/28/2001 | REFUELING OUTAGE - DEFUELED | * | |
| FT CALHOUN 1 | 100 | ||||
| GRAND GULF 1 | 100 | * | |||
| PALO VERDE 1 | 0 | 03/31/2001 | REFUELING OUTAGE | * | |
| PALO VERDE 2 | 99 | * | |||
| PALO VERDE 3 | 99 | ||||
| RIVER BEND 1 | 100 | ||||
| SAN ONOFRE 2 | 100 | ||||
| SAN ONOFRE 3 | 0 | 02/03/2001 | MAINTENANCE OUTAGE | ||
| SOUTH TEXAS 1 | 100 | ||||
| SOUTH TEXAS 2 | 0 | 05/08/2001 | AUTOMATIC REACTOR TRIP FROM 100% POWER DUE TO CLOSURE OF A MAIN FEEDWATER REGULATING VALVE AFTER DIGITAL CONTROL SYSTEM TUNING (Refer to event #37975) | * | 1 |
| WATERFORD 3 | 100 | ||||
| WOLF CREEK 1 | 100 |