Skip to main content

Power Reactor Status Report for March 23, 2001

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 100        
BEAVER VALLEY 2 100     *  
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 0 03/16/2001 REFUELING OUTAGE    
FITZPATRICK 1 100        
GINNA 1 100        
HOPE CREEK 1 100        
INDIAN POINT 2 100        
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 76   COASTDOWN TO REFUELING OUTAGE - LOAD DROP FROM NOMINAL 86% POWER *  
MILLSTONE 2 100        
MILLSTONE 3 0 02/03/2001 REFUELING OUTAGE    
NINE MILE POINT 1 0 03/18/2001 REFUELING OUTAGE    
NINE MILE POINT 2 100        
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100        
PILGRIM 1 100        
SALEM 1 100        
SALEM 2 100        
SEABROOK 1 69   HOLDING POWER FOR PLANNED MAINTENANCE *  
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 0 03/09/2001 REFUELING OUTAGE    
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 100     *  

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 0 03/18/2001 REFUELING OUTAGE    
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 0 02/23/2001 REFUELING OUTAGE    
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 0 02/24/2001 REFUELING OUTAGE - DEFUELED    
HARRIS 1 100        
HATCH 1 100        
HATCH 2 100        
MCGUIRE 1 0 03/09/2001 REFUELING OUTAGE - DEFUELED    
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 0 03/10/2001 REFUELING OUTAGE - DEFUELED    
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 0 02/16/2001 MAINTENANCE OUTAGE    
ROBINSON 2 79   COASTDOWN TO REFUELING OUTAGE *  
SAINT LUCIE 1 100        
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 100        
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 100     *  
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100        
BRAIDWOOD 2 100        
BYRON 1 100        
BYRON 2 96   COASTDOWN TO REFUELING OUTAGE *  
CLINTON 1 100        
COOK 1 100        
COOK 2 100        
DAVIS BESSE 1 100        
DRESDEN 2 100        
DRESDEN 3 100        
DUANE ARNOLD 1 100        
FERMI 2 100     *  
KEWAUNEE 1 96   MAXIMUM POWER LEVEL DUE TO PLUGGED STEAM GENERATOR TUBES    
LASALLE 1 100        
LASALLE 2 99   HOLDING POWER *  
MONTICELLO 1 0 02/25/2001 MAINTENANCE OUTAGE    
PALISADES 1 100        
PERRY 1 8   HOLDING POWER *  
POINT BEACH 1 100        
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 100        
QUAD CITIES 1 100        
QUAD CITIES 2 100     *  

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 0 03/16/2001 REFUELING OUTAGE *  
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 100        
COLUMBIA GENERATING 100        
COMANCHE PEAK 1 89   COASTDOWN TO REFUELING OUTAGE    
COMANCHE PEAK 2 100        
COOPER 1 100        
DIABLO CANYON 1 100        
DIABLO CANYON 2 100        
FT CALHOUN 1 0 03/15/2001 REFUELING OUTAGE    
GRAND GULF 1 100        
PALO VERDE 1 97   COASTDOWN TO REFUELING OUTAGE *  
PALO VERDE 2 99        
PALO VERDE 3 99        
RIVER BEND 1 100        
SAN ONOFRE 2 100        
SAN ONOFRE 3 0 02/03/2001 MAINTENANCE OUTAGE    
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 0 03/06/2001 REFUELING OUTAGE    
WATERFORD 3 100        
WOLF CREEK 1 100        

Page Last Reviewed/Updated Tuesday, August 25, 2026