Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 2001-261

SCIENTECH

910 Clopper Road .Gaithersburg, MD 20878-1399. Phone: 301-258-2410. Fax: 301-258-2463

September 12, 2001

NRC Operations Center
Document Control Desk
1 White Flint North
11555 Rockville Pike
Bethesda, MD 20852

Subject: DEFECT UNDER 10CFR21
Reference NUSI File 21-01-01

Dear Sir or Madam:

The NRC Operations Center Duty Officer was sent a preliminary notification by facsimile on August l3, 2001, indicating that SCIENTECH, Inc.'s subsidiary NUS Instruments, Inc. (NUSI) had determined that a Basic Component, supplied to Rochester Gas & Electric Ginna Station Nuclear Plant may contain a defect reportable under the provisions of 10CFR2l. An evaluation had been initiated and a formal report was to be provided to the NRC within 30 days of the preliminary notification.

The Basic Component is a T and Tave Time Domain Module used to calculate the differential and average temperature of the primary coolant across the core. The module is NUS Instruments Model No. TMD500-08/08/08/08-08-08-01/2, Part No. MBA-E063PA-1, Rev.0. These components have not been supplied to any other utility for use in Safety Related Systems.

Enclosed please find SCIENTECH, Inc.'s subsidiary NUS Instruments, Inc. (NUSI) formal report as a follow up to the preliminary notice.

If you have questions or comments, please feel free to contact us at the numbers listed below.

Sincerely,

Paul Loch
President/COO, SCIENTECH, Inc.
(407) 333-8895

Martin Booska,
Director, Quality Operations
(301) 387-7012

Copy: Mr. Rudy Forgensi, Director, Operating Experience, Rochester Gas and Electric Corporation 1503 Lake Road, Ontario, New York 14519, (Fax 716-771-3325)