Part 21 Report - 1998-633
ACCESSION #: 9811200011
Shared Services Group
P.O. Box 3707
Seattle, WA 98124-2207
November 11, 1998
G-1151-SJA-98-570
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
BOEING
| Reference: | |
| (a) | Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center |
| (b) | NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry |
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
| Very truly yours, Sandra J. Andrews |
Enclosure(s): GTSTRUDL Program Report Form 98.15, 98.16, 98.17, 98.18, 98.19, 98.20.
| Georgia Institute of Technology | GT STRUDL [Registered Trademark] |
November 6, 1998
OCT 11 1998
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O.Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 98.15, 98.16, 98.17, 98.18,98.19,98.20, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sip and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the Acknowledgement Form.
| Best regards, CASE Center David C. Key |
Enclosures
Computer Aided Structural Engineering Center
School of Civil & Environmental Engineering
Atlanta, Georgia 30332-0355 USA
Phone: (404) 894-2260
Fax: (404) 894-8014
casec@ce.gatech.edu
A Unit of the University System of Georgia
GTSTRUDL Program Report Form
GPRF No.: 98,15
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
x URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
MINOR Problem can be worked around or problem poses high frustration factor.
INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed November 2, 1998
Date Notification Sent
Computers All
Operating System All
Versions: 94.01 and later
Target Release for Correction: 98.02
Signature Title
R & D Division
Michael H. Swanger
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2. 2
GTSTRUDL Program Report Form
(Continued)
GPRF No.: 98.15
DATE:
DESCRIPTION:
The use of IPCABLE elements and rigid body elements together in the same model may cause the PERFORM CABLE PRE-STRESS ANALYSIS and the NONLINEAR ANALYSIS commands to abort.
Work Around
If rigid body effects are desired in models that contain IPCABLE elements, use very stiff members or finite elements rather than rigid body elements.
GTSTRUDL User Reference Manual Sections:
Nonlinear Static Analysis Section 2.5, Volume 3, GTSTRUDL Reference Manual.
Nonlinear Static Analysis of Cable Structures Section 2.6.3, Volume 3, GTSTRUDL Reference Manual.
Joint Constraints - Rigid Bodies and Joint Tics Section 2.6.4. Volume 3, GTSTRUDL Reference Manual.
Rev. 2. 2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers ALL
Operating System ALL
Version All versions thru 9801
Target Release for Correction 9901
Director, R&D
Signature Title
R & D Division
Kenneth Will
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
The DEAD LOAD command will abort if a member in the member list has zero length.
Workaround:
Correct the coordinates or incidences of the members which have zero length. The length of the members can be output with the PRINT MEMBER LENGTH command.
Applicable Sections of the Documentation:
Volume 1 of the GTSTRUDL USER'S MANUAL:
DEAD LOAD Section 2.1.11.3.1
PRINT MEMBER LENGTH Section 2.1.14.2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
_ URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
X SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers ALL
Operating System ALL
Version 9101 thru 9801
Target Release for Correction 9901
Director, R&D
Signature Title
R & D Division
Kenneth Will
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
The MOVE OBJECT command will incorrectly compute the length of members as being zero. This error does occurs if the model has been created or modified in GTMENU prior to issuing the MOVE command. The user is informed that the error has occurred as shown in the output below:
MOVE OBJECT 'ROT' ROTATE Z 10.0 ABOUT JOI 1
**** STRUDL ERROR IN.22 - ZERO LENGTH SPECIFIED FOR MEMBER 1 SCAN MODE ENTERED.
The user can issue the PRINT MEMBER LENGTH command to verify that the member's length has been computed to be zero. If the above error message occurs, the user should verify that the length of the member is zero by printing the joint coordinates and computing the length of the member.
Workaround:
If the above error has occurred, the user can go to GTMENU and EDIT JOINT COORDINATES but then CANCEL the editing of the coordinates. The purpose of this is to cause GTMENU to believe that a change has been made to the model so that when then model is translated back to Command Mode, PRINT MEMBER LENGTH will no longer indicate that the members have zero length. The user should then issue the command SCAN OFF before proceeding to perform other computations.
Applicable Sections of the Documentation:
Volume 1 of the GTSTRUDL USER'S MANUAL:
MOVE OBJECT Section 2.1.6.7.4
PRINT MEMBER LENGTH Section 2.1.14.2
GTMENU - Volume 2 of 2 of the 9801 Release Guide
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
_ URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers ALL
Operating System ALL
Version 8701 thru 9801
Target Release for Correction 9901
Director, R&D
Signature Title
R & D Division
Kenneth Will
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
Edge loads on the TRIDIMENSIONAL element IPSQ (20 node solid) will produce incorrect results. The generated loads will be applied in the wrong directions and will not satisfy equilibrium. Users can verify that the results are incorrect by the LIST REACTIONS and LIST SUM REACTIONS commands.
Workaround:
Use the other 20 node TRIDIMENSIONAL element, IPQS, which also has 20 nodes.
Applicable Section of the Documentation:
Volume 3 of the GTSTRUDL USER'S MANUAL - EDGE LOADS - SECTION 2.3.5.4.2.1
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
MINOR Problem can be worked around or problem poses high frustration factor.
INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed November 3, 1998
Date Notification Sent
Computers All
Operating System All
Version All versions prior and including 9801 NT
Target Release for Correction 9901
Senior Software Engineer
Signature Title
R & D Division
Hamid Zand
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
Applicable GT STRUDL Commands:
CREATE LOADING COMBINATION Section 2.1.11.3.4 of Volume 1
LOADING COMBINATION Section 2.1.11.5 of Volume 1
COMBINE Section 2.1.11.6 of Volume 1
Explanation:
In the above loading combination commands, when the loading contribution factor for the last loading ID is not specified, the last loading ID is ignored and no error message is issued.
Applicable GT STRUDL User's Manual:
Volume 1 Section 2.1.11.3.4
Volume 1 Section 2.1.11.5
Volume 1 Section 2.1.11.6
Example:
CREATE LOADING COMBINATIONS 'A' SPECIFICATION 'LL' 0.75 'DL' 0.75 'WL'
In the above loading combination 'A', the factor 0.75 was not specified for the loading 'WL' by mistake. Unfortunately the program did not issue an error message and the loading 'WL' was ignored for the loading combination 'A'. The final components for the loading combination 'A' are the loading 'LL' with the 0.75 contribution factor and the loading 'DL' with the 0.75 contribution factor.
User can verify their loading combination input by issuing the PRINT LOADING DATA command (Section 2.1.14.2 of Volume 1).
Rev. 2.2
GTSTRUDL Program Report Form
GPRF No.:
DATE:
FROM: Computer-Aided Structural Engineering Center
Georgia Institute of Technology
Atlanta, Georgia 30332-0355
SEVERITY LEVEL:
X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job.
_ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task.
_ MINOR Problem can be worked around or problem poses high frustration factor.
_ INFORMATIVE Documentation error, program usage tip, user inconveniences.
Date Problem Confirmed
Date Notification Sent
Computers ALL
Operating System ALL
Version All versions thru 9801
Target Release for Correction 9901
Director, R&D
Signature Title
R & D Division
Kenneth Will
Typed or Printed Name Date of Signature
Signature Title
Professional Services Division
Typed or Printed Name Date of Signature
Rev. 2.2
GTSTRUDL Program Report Form
(Continued)
GPRF No.:
DATE:
DESCRIPTION:
If a member without the specified diagram is first in the member list of an OVERLAY DIAGRAM command, then none of the diagrams produced can be labelled in the CURSOR mode of the Scope Environment and the LABEL OVERLAY command will not label the diagrams.
Workaround:
Specify only those members which have the specified diagrams in the member list. For instance, if a structure has a mixture of space truss and space frame members, specify the OVERLAY DIAGRAM MOM Z MEMBERS list where list contains only the space frame members since the space truss members have only FORCE X results.
Applicable Section of the Documentation:
Volume 3 of the GTSTRUDL USER'S MANUAL:
OVERLAY DIAGRAM Section 2.7.6.8
CURSOR mode Section 2.7.6.13
LABEL OVERLAY Secion 2.7.6.7
*** END OF DOCUMENT ***