Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1998-431

ACCESSION #: 9805260384 VALCOR [Registered Trademark] VALCOR ENGINEERING CORPORATION 2 Lawrence Road o Springfield, New Jersey 07081 USA o 973-467-8400 Fax: 973-467-8382 o Internet: http://www.valcor.com May 19,1998 Operations Center Nuclear Regulatory Commission Washington, D.C. 20555 Attn: Mr. Bob Stranski Fax: 301-816-5151 SUBJECT: 10CFR21 Reporting of Delay-In-Closing Problem of Valcor Valve, Part Number V70900-65-11. Confirming our telephone conversation earlier this afternoon, Valcor is submitting the attached report "Summary of V70900-65-11 Delay-In-Closing Problem Due To Residual Magnetism" under the provision of 10 CFR Part 21. The report contains all the elements required per 21.21.d.4 of the Part 21. Please feel free to call me at 973-467-8400, extension 284 if you need any additional information. VALCOR ENGINEERING CORPORATION Jimmy Shieh Quality Assurance Director cc: H. Loran D. Shave B. Matiez C. DelPomo L. Olsen, PP&L VALCOR [Registered Trademark] May 19, 1998 VALCOR ENGINEERING CORPORATION Summary of V70900-65-11 Delay-In-Closing Problem Due To Residual Magnetism Following 6 to 18 months of continuously energized service, 3 units of Valcor Model V70900-65-11 air pilot valves have reportedly failed to stroke closed immediately upon de-energization when installed in their respective systems. Despite best efforts, the delays in closing have not been able to be replicated outside of the plant system. Delays in closing have ranged from 1 to 5 minutes. Upon investigation, a potential cause of the delayed closing is the possible susceptibility of this particular model to the effects of residual magnetism. Delayed closing may occur when the air gap between the plunger and the stop becomes too small or if the plunger makes contact with the stop. Extended periods of continuously energized service, and subsequent compression setting of the O-ring seat, may induce the small air gap condition. As a result of the small air gap, the valve may then be subject to residual magnetism forces, which tend to prevent closure of the valve upon de-energization. Opening operation of the valve is not affected. The V70900-65-11 is an AC-powered version and is the only version of the V70900-65 air pilot series subject to this effect. Only 46 units of this particular model have been delivered, all to PP&L's Susquehanna Nuclear Power Plant. All of these units have been, or are scheduled to be, modified by Valcor to positively eliminate the potential for residual magnetism effects. The corrective action includes the insertion of a non-magnetic residual washer between the plunger and the stop, and also includes modification of the assembly procedure to specifically measure and control the air gap. This results in a higher drop out voltage for the valve. Other corrective action, which has already been accomplished, includes the modification of the reference design to add the residual washer to units built in the future. The initial report of a potential problem with one valve was received by Valcor in September of 1997. Subsequent investigations by the utility and by Valcor led Valcor to believe that a possible problem might exist, and Valcor initiated a 10CFR21 evaluation in accordance with internal procedures in late March, 1998. Further plant testing in April and May of 1998 identified 2 other valves which appeared to delay in closing. GENERAL INFORMATION or OTHER EVENT NUMBER: 34262 LICENSEE: VALCOR ENGINEERING CORPORATION NOTIFICATION DATE: 05/19/98 CITY: SPRINGFIELD REGION: 1 NOTIFICATION TIME: 15:59[ET] COUNTY: STATE: NJ EVENT DATE: 05/19/98 LICENSE#: AGREEMENT: N EVENT TIME: 00:00[EDT] DOCKET: LAST UPDATE DATE: 05/19/98 NOTIFICATIONS GENE KELLY RDO NRC NOTIFIED BY: JIMMY SHIEH VERN HODGE NRR HQ OPS OFFICER: BOB STRANSKY EMERGENCY CLASS: NOT APPLICABLE 10 CFR SECTION: CDEG 21.21(c)(3)(i) DEFECTS/NONCOMPLIANCE EVENT TEXT 10 CFR PART 21 REPORT FOLLOWING 6 TO 18 MONTHS OF CONTINUOUS ENERGIZED SERVICE, THREE VALCOR MODEL V70900-65-11 AIR PILOT VALVES FAILED TO STROKE CLOSED IMMEDIATELY UPON DEENERGIZATION WHEN INSTALLED IN THEIR RESPECTIVE SYSTEMS. DELAYS IN CLOSING HAVE RANGED FROM ONE TO FIVE MINUTES. DESPITE BEST EFFORTS, THE VENDOR REPORTED THAT CLOSING DELAYS HAVE NOT BEEN REPLICATED OUTSIDE OF THE PLANT SYSTEMS. THE VENDOR REPORTED THAT A POTENTIAL CAUSE OF THE DELAYED CLOSING IS THE POSSIBLE SUSCEPTIBILITY OF THIS PARTICULAR MODEL TO THE EFFECTS OF RESIDUAL MAGNETISM. DELAYED CLOSING MAY OCCUR WHEN THE AIR GAP BETWEEN THE PLUNGER AND THE STOP BECOMES TOO SMALL OR IF THE PLUNGER MAKES CONTACT WITH THE STOP. EXTENDED PERIODS OF CONTINUOUSLY ENERGIZED SERVICE AND SUBSEQUENT COMPRESSION SETTING OF THE O-RING SEAT MAY INDUCE THE SMALL AIR GAP CONDITION. AS A RESULT OF THE SMALL AIR GAP, THE VALVE MAY THEN BE SUBJECT TO RESIDUAL MAGNETISM FORCES, WHICH TEND TO PREVENT CLOSURE OF THE VALVE UPON DEENERGIZATION. OPENING OPERATION OF THE VALVE IS NOT AFFECTED. THE V70900-65-11 IS AN AC POWERED VERSION AND IS THE ONLY VERSION OF THE V70900-65 AIR PILOT SERIES SUBJECT TO THIS EFFECT. ONLY 46 UNITS OF THIS PARTICULAR MODEL HAVE BEEN DELIVERED, ALL TO THE SUSQUEHANNA STEAM ELECTRIC STATION. ALL OF THE UNIT HAVE BEEN, OR ARE SCHEDULED TO BE, MODIFIED BY VALCOR TO ELIMINATE THE POTENTIAL FOR RESIDUAL MAGNETISM EFFECTS. *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021