Part 21 Report - 1998-133
ACCESSION #: 9803250049
| The Boeing Company P.O. Box 3707 Seattle. WA 98124-2207 |
March 18, 1998
G-1151-SJA-98-157
Document Control Desk
United States Nuclear Regulatory Commission
Washington, D.C. 20555
| Reference: | a) | Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center |
| BOEING | b) | NRC Letter Docket No. 99901227 dated August 12, 1992; L.J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry |
Dear Sir or Madam:
In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified:
Reactor Controls, Inc.
Echo Energy Consultants, Inc.
Nuclear Applications and Systems Analysis Company (Japan)
Nuclear Power Services
Error notices have been sent to our other former customers.
| Very truly yours, Sandra J. Andrews |
Enclosure(s): GTSTRUDL Program report forms 98.05 and 98.06
| Georgia Institute of Technology | GT STRUDL "Trade Mark" |
| March 12, 1998 | MAR 17 1998 |
| CONTRACTS |
Attention: Nuclear Administrator
Boeing Information & Support Services
P.O. Box 24346, M/S 7A-33
Seattle, Washington 98124-0346
RE: GT STRUDL
Dear Sir or Madam:
Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORMS 98.05 and 98.06, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report.
Thank you for reviewing the Program Report and for returning the Acknowledgement Form.
| Best regards, CASE Center David C. Key |
Enclosures
| Computer Aided Structural Engineering Center | Phone: (404) 894-2260 |
| School of Civil & Environmental Engineering | Fax: (404) 894-8014 |
| Atlanta, Georgia 30332-0355 USA | cases@ce.gatech.edu |
A Unit of the University System of Georgia
| GTSTRUDL Program Report Form | ||
| GPRF No.: 98.05 | ||
| DATE: | ||
| FROM: | Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 | |
| SEVERITY LEVEL: | ||
| X | URGENT | Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. |
| SERIOUS | Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. | |
| MINOR | Problem can be worked around or problem poses high frustration factor. | |
| INFORMATIVE | Documentation error, program usage tip, user inconveniences. | |
| Date Problem Confirmed | March 9, 1998 | |
| Date Notification Sent | ||
| Computers | All | |
| Operating System | All | |
| Versions: | All versions prior to 98.02 | |
| Target Release for Correction: | 98.02 | |
| Mgr. ASD | ||
| Signature | Title | |
| R & D Division | ||
| Michael H. Swanger | ||
| Typed or Printed Name | Date of signature | |
| Signature | Title | |
| Professional Services Division | ||
| Typed or Printed Name | Date of Signature | |
Rev. 2.2
GTSTRUDL Program Report Form (Continued)
| GPRF No.: | |
| DATE: |
DESCRIPTION:
Any member force load applied to PLANE FRAME members produces incorrect results if the member properties include non-zero shear center eccentricity values (EY, EZ) that place the shear center outside the global plane of the structure. For example, this problem will occur for unequal-leg angle cross sections and channel cross sections having beta -angle = 0.0 in PLANE FRAME XY structures because the shear centers for these cross sections lie outside the global plane of the structure. On the other hand, this problem will not occur for T sections having beta-angle = 0.0 in PLANE FRAME XY structures because the shear center lies in the plane of the web which corresponds to the global plane of the structure.
This problem does not occur with PLANE TRUSS, PLANE GRID, SPACE FRAME, or SPACE TRUSS members, nor does the problem occur for member temperature or member distortion loads applied to any type of member in a plane structure.
GTSTRUDL User Reference Manual Sections:
| The TYPE Command | Section 2.1.5.2.2, Volume 1, GTSTRUDL Reference Manual. | |
| Member/Element Properties | Section 2.1.9, Volume 1, GTSTRUDL Reference Manual. | |
| The MEMBER LOADS Command | Section 2.1.11.4.3, Volume 1, GTSTRUDL Reference Manual. |
Rev. 2.2
GTSTRUDL Program Report Form
| GPRF No.: | |||
| DATE: | |||
| FROM: | Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 | ||
| SEVERITY LEVEL: | |||
| __ | URGENT | Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. | |
| X | SERIOUS | Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. | |
| __ | MINOR | Problem can be worked around or problem poses high frustration factor. | |
| __ | INFORMATIVE | Documentation error, program usage tip, user inconveniences. | |
| Date Problem Confirmed March 12, 1998 | |||
| Date Notification Sent | |||
| Computers PC | |||
| Operating System Windows NT or 95 | |||
| Version 9701 NT | |||
| Target Release for Correction 9801 NT | |||
| Senior Software Engineer | |||
| Signature | Title | ||
| R & D Division | |||
| Hamid Zand | |||
| Typed or Printed Name | Date of Signature | ||
| Signature | Title | ||
| Professional Services Division | |||
| Typed or Printed Name | Date of Signature | ||
Rev. 2.2
GTSTRUDL Program Report Form (Continued)
| GPRF No.: | |||
| DATE: | |||
| DESCRIPTION: | |||
| Steel Design Check Member | |||
| Applicable GT STRUDL Command: | |||
| PARAMETERS | |||
| Explanation: | |||
| In some instances of specifying the PARAMETER values in Metric unit, the PRINT PARAMETER VALUES, SELECT, or CHECK command may result in an abort. The following values in Millimeter units may cause an abort when specified for the Parameter LY or LZ. | |||
| 9500.0 4750.0 1367.0 1211.27 683.5 | |||
| Workaround: | |||
| Specify the Parameter value in INCH units. | |||
| Applicable GT STRUDL User's Manual: | |||
| Volume 2A Section 2.1 | |||
| Example: | |||
| The following example may cause an abort: | |||
| UNITS MM PARAMETER | |||
| LZ | 9500.0 | MEMBER 20 | |
| CHECK MEMBER 20 | |||
Rev. 2.2
*** END OF DOCUMENT ***