LICENSEE: ILLINOIS POWER CO. SITE: CLINTON 1 EN NUMBER:31496 DOCKET: 05000461 EVENT DATE: 12-20-96 RX TYPE: BWR EVENT TIME: 00:00 VENDORS: GE-6 NOTIFY DATE: 12-20-96 EMERGENCY CLASS: N/A REGION: 3 STATE: IL TIME: 21:54 OPS OFFICER: RUDY KARSCH 10 CFR SECTION: CDEG 21.21(c)(3)(i) DEFECTS/NONCOMPLIANCE UNIT SCRAM RX INIT INITIAL MODE CURR CURRENT MODE CODE CRIT PWR PWR 1 N N 0 REFUELING 0 REFUELING WESTINGHOUSE DHP CIRCUIT BREAKERS FAILED TO CLOSE ON DEMAND DUE TO A DIRTY AND BINDING MOTOR CUT-OFF SWITCH AND SPRING CHARGE INDICATOR MECHANISM. THE VENDOR LITERATURE FAILED TO PROVIDE GUIDANCE FOR INSPECTING, CLEANING, ADJUSTING, OR LUBRICATING THESE VITAL COMPONENTS. THE LICENSEE HAS EVALUATED THIS ISSUE AND CONCLUDES THAT IT IS REPORTABLE UNDER THE PROVISIONS OF 10 CFR PART 21.