Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1996-642

ACCESSION #: 9610160180 Information & Support Services P.O. Box 3707 Seattle, WA 98124-2207 October 3, 1996 G-1151-SJA-96-615 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 BOEING Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Tenera Engineering Services Gibbs & Hill, Inc. Holtec International*_/ Error notices have been sent to our other former customers. _________________________ *_/ Please note: GTSTRUDL Program Report Form 96.20 has been returned to Boeing by the Post Office as undeliverable. Our efforts to obtain a current mailing address for Holtec International have been unsuccessful. _________________________ Very truly yours, Sandra J. Andrews Nuclear Administrator Phone: (206) 865-6248 FAX (206) 865-4851 15004 Mail Stop: 7A-33, or e-mail: Sandra.Andrews@PSS.Boeing.com Enclosure(s): GTSTRUDL Program Report Form No. 96.21 Georgia Tech Computer Aided Structural Engineering Center Georgia institute of Technology School of Civil & Environmental Engineering Atlanta, Georgia 30332-0355 USA 404 o 894 o 2260 404 o 894 o 8014 FAX September 23, 1996 Attention: Nuclear Administrator Boeing Information & Support Services P.O.Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM No. 96.21 and a VENDOR ACKNOWLEDGMENT FORM. Please sign and return the VENDOR AC- KNOWLEDGMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgment Form. Best regards, CASE Center Lawrence F. Kahn Director of Professional Services CL/tlk Enclosures An Equal Education and Employment Opportunity Institution A Unit of the University System of Georgia GTSTRUDL Program Report Form GPRF No.: DATE: FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _ MINOR Problem can be worked around or problem poses high frustration factor. _ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed Date Notification Sent Computers All Operating System All Version 93.01 and later Target Release for Correction 96.02 Mgr. ASD Signature Title R & D Division Michael H. Swanger Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: DATE: DESCRIPTION: The LIST MAXIMUM REACTIONS command may abort or produce incorrect results if active length and force units are specified to be other than INCHES and POUNDS respectively. This problem may be avoided by specifying the UNITS INCHES POUNDS command prior to giving the LIST MAXIMUM REACTIONS command: UNITS INCHES POUNDS LIST MAXIMUM REACTIONS ... Applicable sections of the User's Manual: LIST MAXIMUM REACTION Command Section 2.1.14.4.2, Volume 1, Rev. N Input/Output Units Specification Section 2.1.2.6, Volume 1 Rev. 2.2 *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021