Skip to main content

Part 21 Report - 1996-232

ACCESSION #: 9604150413 Information & Support Services P.O. Box 3707 Seattle, WA 98124-2207 April 8, 1996 G-1151-SJA-96-208 BOEING Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Tenera Engineering Services Gibbs & Hill, Inc. Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator G-1151 M/S 7A-33 (206) 865-6248 Attachment(s): GTSTRUDL Program Report Form Nos. 96.12 and 96.13 Georgia Tech Computer Aided Structural Engineering Center Georgia Institute of Technology School of Civil & Environmental Engineering Atlanta, Georgia 30332-0355 USA 404o894o2260 404o894o8014 FAX April 2, 1996 APR 08 1996 CONTRACTS Attention: Nuclear Administrator Boeing Information & Support Services P.O.Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM Nos. 96.12 and 96.13 and a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center Catherine Lee Configuration Control Manager CL/jhb Enclosures An Equal Education and Employment A Unit of the University System Opportunity Institution of Georgia GTSTRUDL Program Report Form GPRF No.: 96.12 DATE: April 1, 1996 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _ MINOR Problem can be worked around or problem poses high frustration factor. _ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed April 1, 1996 Date Notification Sent April 3, 1996 Computers ALL Operating System ALL Version 9001 thru 9501 Target Release for Correction 9602 Director, R&D Signature Title R & D Division Kenneth Will Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 96.12 DATE: April 1, 1996 DESCRIPTION: If a model contain variable member properties and the model is brought into GTModeler, an abort may occur or the Section Property Groups in GTModeler will contain incorrect properties. The user may verify the properties by using the PRINT MEMBER PROPERTIES command or using the EDIT PROPERTIES (EDI - PROP) menu in GTModeler. Workaround: Do not use GTMODELER when the model contains variable member properties. Applicable Section of the Documentation: GTMODELER - Volume 6 of the GTSTRUDL Users Manual GEN - PROP - SECTN - VAR - Section 9.2.3 EDI - PROP - SECTN - SELECT and LIST - Section 13.3.2 Volume 1 of the GTSTRUDL Users Manual PRINT MEMBER PROPERTIES - Section 2.1.9.2 MEMBER PROPERTIES VARIABLE - Section 2.1.14.2 Rev. 2.2 GTSTRLTDL Program Report Form GPRF No.: 96-13 DATE: April 1, 1996 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: x URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _ MINOR Problem can be worked around or problem poses high frustration factor. _ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed April 1. 1996 Date Notification Sent April 3. 1996 Computers PC Operating System DOS Version 96.01 Target Release for Correction 96-02 Developer Signature Title R & D Division Robert Abernathy Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 96.13 DATE: April 1, 1996 DESCRIPTION: When using the new feature "LIST SECTION DISPLACEMENT option WITH MAXIMUM", the "Disp/length" (displacement value divided by member length) values are incorrect, except when the active units are INCHES. To be able to use the "Disp/length" information, use the following senario: UNITS INCHES LIST SECTION DISPLACEMENT CHORD WITH MAXIMUM $ Return to the previous length units, e.g. UNITS METERS Rev. 2.2 *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021