Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Morning Report for May 10, 2004

Headquarters Daily Report

To top of page

REGION II

STEAM GENERATOR TUBES DEGRADED - UPDATE

Licensee/Facility:

SOUTHERN NUCLEAR OPERATING CO., INC.
Vogtle 2
WAYNESBORO, Georgia
Dockets: 05000425
[2] W-4-LP
License No:
Notification:

MR Number: 2-2004-0006
Date: 05/10/2004

Call from SRI

Discussion:

This Morning Report provides updated information concerning confirmed outer diameter (OD) circumferential cracks in Unit 2 steam generator (SG) tubes. Unit 2 is currently in a scheduled refueling outage. The licensee has completed 100% eddy current testing (ECT) of SG hot leg tubes in all four SGs. The results of the ECT identified one tube in SG 1, two tubes in SG 2, three tubes in SG 3, and two tubes in SG 4 with OD cracking. All tubes were stabilized and plugged. Two tubes have been pulled in SG 2 for further analysis to determine the degradation mechanism.

The highest indication by ECT of thru-wall cracking was 38%. This tube was one of the two tubes pulled so the actual thru-wall percentage will not be known until analysis is complete.

This information is current as of 12:00 p.m. 5/10/2004.