Morning Report for June 11, 2001
Headquarters Daily Report JUNE 11, 2001 *************************************************************************** REPORT NEGATIVE NO INPUT ATTACHED INPUT RECEIVED RECEIVED HEADQUARTERS X REGION I X REGION II X REGION III X REGION IV X PRIORITY ATTENTION REQUIRED MORNING REPORT - HEADQUARTERS JUNE 11, 2001 Licensee/Facility: Notification: Part 21 Database MR Number: H-01-0042 Conval Date: 06/11/01 Somers,Connecticut Subject: Part 21 - Flow coefficients less than procurement specification for ball check valves Discussion: VENDOR: Conval PT21 FILE NO: m1-20-0 DATE OF DOCUMENT: 05/23/01 ACCESSION NUMBER: ML011500422 SOURCE DOCUMENT: EN 38027 REVIEWER: REXB, V. Hodge The valve vendor Conval reports a noncompliance involving flow coefficients for ball check valves with the angle pattern or tee pattern body style used in charging water riser isolation and scram discharge riser isolation applications. The vendor learned from tests that the flow coefficient values for both styles are less than 1.5, though procurement documents specify higher values. In one case, scram time increased from 1.5 seconds to 2 seconds. The vendor states that it notified both the affected domestic nuclear power plants at Oyster Creek and Nine Mile Point Unit 1. The NRC will post ensuing reports on this subject on its Web site at http://www.nrc.gov/NRC/PUBLIC/PART21/2001. Contact: V. Hodge, NRR 301-415-1861 E-mail: cvh@nrc.gov _
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021